Traulsen VPS48S, VPS54S, VPS66S, VPS90S, VPS114S, VPS54J, VPS66J, VPS72J, VPS90J, VPS120J

Page 3

II. RECEIPT INSPECTION

III. INSTALLATION (contd)

All Traulsen products are factory tested for performance

III. a – LOCATION & CLEARANCE (contd):

and are free from defects when shipped. The utmost

 

care has been taken in crating this product to protect

 

against damage in transit. Casters or legs are boxed

 

inside to prevent damage.

 

Upon delivery carefully inspect your Traulsen unit for

 

shipping damage. If any is detected, note it on the

 

carriers Bill Of Lading and save all the crating

 

materials. File a freight claim immediately. If concealed

 

damage is discovered at installation, contact the

 

carrier and file a freight claim then. Under no

 

circumstances may any damaged unit(s) be returned

 

to Traulsen without proper prior authorization.

 

III. INSTALLATION

 

NOTE: If the unit is installed or stored near any incomplete concrete or tile work see the note at the end of section VI.b

III.a – LOCATION & CLEARANCE:

Select a location for your Traulsen VPS unit away from extreme heat or cold. These units are designed to operate in an environment of 86°F (30°C) or less.

Locate the unit so that air drafts (such as heat, A/C or ventilation) do not blow on or over the rail area.

The condensing unit of your Traulsen VPS unit MUST have adequate air circulation. Therefore, do not store anything within of 31of the condensing unit louvers (located on the unit front). Allow enough clearance between the unit and the side wall so that the doors may open a minimum of 90°. Standard rail models require at least 61-3/8vertical clearance (16-1/2above the unit) to allow the rail cover to open completely (see figures 1 & 2).

Fig. 1 Section View - Standard Rail Models

Fig. 2 Section View - Jumbo Rail Models

III.b - POWER SUPPLY:

WARNING

Electrical Shock Hazard

Do not remove ground prong

Do not use an adapter or extension cord

Plug only into a 3-prong

grounding receptacle

This unit requires a dedicated circuit and 3-prong grounding receptacle.

Model

NEMA Receptacle

Number

Required

VPS48

5-15R

VPS54

5-15R

VPS66

5-15R

VPS72

5-15R

VPS90

5-20R

VPS114

5-20R

VPS120

5-20R

Verify the supply voltage prior to installation. Do not plug the unit in before reading this entire manual.

III.c - PACKAGING:

Traulsen VPS units are shipped from the factory on a wooden pallet and protected by a crate. Remove the crate but leave the unit secured to the pallet until it reaches its final location. Remove (4) lag screws that secure the unit to the pallet. Lift and support the unit

-2-

Image 3
Contents Jumbo 20 Front to Back Rail Models Models Standard 12 Front to Back Rail ModelsSerial TAG Table of ContentsII. Receipt Inspection III. InstallationIII. Installation cont’d Daily Operation IV. First Time START-UPVI. Routine Cleaning VII. c Gasket Replacement VII. Service & Maintenance InformationVII. Service & Maintenance Information cont’d Lock Unlock VIII. Trouble Shooting Guide Operational Symptom Potential CAUSE/REMEDYIX. Operational Guidelines PAN Capacities VPS48S VPS54S VPS66S VPS72S VPS90S VPS114SVPS54J VPS66J VPS72J VPS90J VPS120J VPS48S VPS54S VPS66S VPS72S VPS90S VPS114S XI. SPARE/REPLACEMENT Parts ListingNot shown to scale XII. Adapter BAR ChartStandard Domestic Warranty XIII. Warranty InformationXIV. Index Hours of Operation

VPS54J, VPS66J, VPS72J, VPS48S, VPS54S, VPS66S, VPS90S, VPS114S, VPS54J, VPS66J, VPS72J, VPS90J, VPS120J specifications

The Traulsen VPS series is renowned in the commercial refrigeration industry, offering a range of versatile and reliable reach-in refrigerators. The models VPS48S, VPS54S, VPS66S, VPS90S, VPS114S, VPS54J, VPS66J, VPS72J, VPS90J, and VPS120J are designed for optimal performance in busy kitchen environments, making them ideal for restaurants, catering services, and food storage facilities.

One of the standout features of the VPS series is its exceptional durability. Constructed with high-quality stainless steel exteriors and interiors, these models resist corrosion and ensure easy cleaning, which is crucial in maintaining hygiene standards. The reinforced doors are built for repeated use, equipped with magnetic gaskets that provide a tight seal to preserve interior temperature.

The cooling technology employed in the VPS series is designed for efficiency and reliability. These refrigerators utilize a high-performance refrigeration system that maintains consistent temperatures between 33°F and 41°F. The units incorporate environmentally-friendly refrigerants, making them not only efficient but also compliant with regulatory standards. Additionally, the self-contained refrigeration system streamlines maintenance and reduces the risk of refrigerant leaks.

The VPS series also features an intuitive electronic control system that provides precise temperature management. This system allows for easy adjustments and features digital displays that show current and set temperatures, enhancing user convenience. The automatic LED interior lighting offers excellent visibility, making it easy to locate stored items quickly.

With various sizes available, including the VPS48S (48 inches), VPS54S (54 inches), VPS66S (66 inches), VPS90S (90 inches), VPS114S (114 inches), VPS54J, VPS66J, VPS72J, VPS90J, and VPS120J, restaurant owners can choose the model that best fits their kitchen layout and storage needs. All models are designed with strategically arranged shelving to maximize storage space while accommodating various container sizes.

In conclusion, the Traulsen VPS series stands out for its robust construction, advanced cooling technology, and user-friendly features. These reach-in refrigerators are a solid investment for any food service operation looking to ensure excellence in food preservation and accessibility.