True Manufacturing Company TCGD-50 Electrical Instructions, Startup, Replacement Parts

Page 8

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

ELECTRICAL INSTRUCTIONS

Step 4

NOTE

Hard wiring is required on standard "Dry" Bakery Cases.

NOTE

Optional 12" (30.5 cm) corded model available, fac- tory installed only. (exterior scale receptacle will not be included with this option.

A.Before your new unit is connected to a power supply, check the incoming voltage with a volt- meter. If anything less than 100% of the rated voltage for operation is noted, correct immedi- ately.

Refer to cabinet data plate for voltage.

True requires that a sole use circuit be dedicated for the unit.

WARNING

If your bakery case includes optional 12" (30 cm) power supply cord, ground should not be removed!

NOTE

To reference wiring diagram - wiring diagram is positioned on the ballast box inside lower rear of the cabinet.

STARTUP

Step 5

A.Verify that the cabinet lights are working. Bakery cases are shipped with light switches in the "on" position. The toggle switch is located lower right corer at the rear.

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your unit. If at any time during the life of your dis- play case, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cabi- net. Call Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A. & Canada only) or call: (636)-240-2400.

NON-REFRIGERATED "DRY" CURVED

GLASS DISPLAY CASES (hard wired models only)

Hard wired Bakery Cases are equipped with a service receptacle (found on the upper right cabinet backside). No elec- trical load greater than 4.0 amps should be connected to it.

6

www.truemfg.com

6

Image 8
Contents Curved Glass Display Cases DRY Bakery Page Safety Precautions Proper Disposal of the Display Case USE of Extension CordsHard wiring is required on standard Dry Display Cases For models with Optional 12 30.5 cm cordInstallation / Operation Instructions Ownership Required ToolsUncrating StepTools Required LocatingLeveling Replacement Parts Electrical InstructionsStartup NON-REFRIGERATED DRY CurvedConductors and Circuits Shelving Installation DRY Bakery Shelf InstallationFor lights to work. If less than Attached caps are plugged intoCastor Installation Tools Required Unit and checkRefer to image 1 for placement of Formica panels Optional Installing Optional Formica KITFormica KIT Installation Formica KIT Components Cabinet Cleaning Optional Sealing Cabinet to FloorInterior TOP Bulb Replacement Light Bulb ReplacementShelf Mounted Bulb Replacement ONE Year Parts & Labor Warranty