Troubleshooting Guide
Problem | Probable Cause | Remedy |
DISPENSER IS TOTALLY | No power present at the | Check the power circuit for a blown |
INOPERATIVE | source. | fuse or tripped circuit breaker. Check |
|
| the supply line for the proper |
|
| amperage and voltage |
|
| ratings.....dedicated 15 amps /115 |
|
| volts. |
| Power is present at the | Check the power cord connection |
| source...dispenser is still | located behind the front splash panel. |
| inoperative. |
|
DISPENSER WILL NOT | Refrigeration shut off switch | Refrigeration shut off switch is |
COOL | is in the off position. | located on the top of the dispenser . |
|
| This switch will disable the |
Drink temperature should be |
| compressor and the condenser fan |
| motor. Be sure the switch is in the on | |
|
| position. |
| Low water bath level. | Check water bath level. If 2 gallons |
|
| or more are added, cause of problem |
|
| has been confirmed. |
| Depleted ice bank ( not | Check compressor. If running, allow |
| applicable after period of | the system time to recover |
| heavy usage.) | (approximately 1 hour). If |
|
| compressor is not running or the |
|
| system is not recovering see the |
|
| Refrigeration System |
|
| Troubleshooting section. |
| Defective Ice bank control. | See Refrigeration System |
|
| Troubleshooting section. |
WITH POWER PRESENT, | Key lock switch in the OFF | Check position of the key lock |
UNIT WILL NOT DISPENSE | position. | switch. Check for loose wire |
ALL VALVES. |
| connections. Run continuity check, |
|
| replace as needed. |
| Transformer not connected or | Check the connection between the |
| defective. | power strip and the transformer. |
|
| Check transformer output at terminal |
|
| junction on control box for 26 VAC. |
| Fuse blown between the | Check the fuse located in the |
| transformer and voltage | electrical box, left side. This box is |
| regulator boards. | located on the refrigeration deck and |
|
| will require the removal of the upper |
|
| bonnet. Replace fuse as needed. |
10