Cornelius MJ32-4 PB Unit Dispensing, Concentrate only no, Water to ALL Valves, From Single Valve

Page 12

Troubleshooting Guide

Problem

Probable Cause

Remedy

UNIT DISPENSING

No water reaching dispenser

Check line to see if the water is shut

CONCENTRATE ONLY NO

from the water supply line.

off at the source.

WATER TO ALL VALVES

 

 

 

Water pressure over 100 psi or

Install regulator onto incoming water

 

7 bar. High pressure will not

line to reduce the pressure to between

 

allow the water solenoids to

30 and 80 psi. (2-5- bar).

 

open.

 

 

Freeze up of water coil.

Refer to the Refrigeration System

 

 

Troubleshooting section.

FROM SINGLE VALVE

Inoperative or defective push

Check for loose or broken wire

UNIT WILL NOT DISPENSE

button switch, or portion

connections at the switch. Check the

WATER OR

control board.

continuity of switch. Replace as

CONCENTRATE.

 

needed.

 

 

The VRB boards are contained in the

 

Defective Voltage Regulator

electrical box mounted on the

 

(VRB) board.

refrigeration deck.. There is one for

 

 

each valve.

 

 

CAUTION: Access to this panel

 

 

requires the removal of the upper

 

 

bonnet while the dispenser is

 

 

energized and operational.

 

 

Check the power input for 26 VAC

 

 

and the output for 28 VDC.

FROM SINGLE VALVE,

Inoperative water valve

Check to see all wire connections are

UNIT IS DISPENSING

solenoid coil.

secured at the coil. Check power for

CONCENTRATE ONLY.

 

26 VDC. If power is present, coil

 

 

maybe defective , replace as needed.

 

 

Armature maybe stuck, disassemble

 

 

and check function. Return spring

 

 

could also be defective replace as

 

 

needed.

 

Solenoid makes clicking

Disassemble the coil assembly and

 

sound when energized, but

check plunger seal for defects.

 

still does, not function.

Replace as required. Inspect valve

 

 

seat for restrictions.

 

Flow control binding or

Disassemble flow control assembly

 

defective.

and check the spool and sleeve

 

 

assembly . Be sure the spool moves

 

 

freely within the sleeve and there are

 

 

no restrictions.

11

Image 12
Contents Installation & Service Manual Table of Contents General Description Specifications Installation Receiving & UnpackingFill Ice Water Bath Programming Portion Control optional Brixing ConcentrateCleaning & Sanitizing System Cleaning and Sanitizing Equipment and SuppliesDaily Cleaning Maintenance Maintenance Refrigeration SystemIce Water Bath Cleaning Troubleshooting Guide Unit Dispensing Concentrate only noWater to ALL Valves From Single ValveUnit is Dispensing Water only Dispenser is BrixingOUT TOO High OUT TOO LOW Operate When only Water Leaks fromBottom of Dispensing ValveCompressor will not RUNCompressor Runs but No Cooling is TakingNo COOLING. Tripping OverloadAnything on TOP Refrigeration SystemHas Been Running for Extended Period Without Shutting OFF Frozen Water CoilMillennium 4 Valve Schematic Final Assembly Description QTYFinal Assembly Final Assembly Platform Assembly Pump & Bracket Assembly Pump Motor Assembly Dispensing Assembly Valve Block Assembly Valve Block Assembly Electrical Box Assembly Voltage Regulator Assembly, SLJ1000-2 Portion Control Assembly Portion Control Electrical Diagram Millennium Model MJ30-4 Recommended Spare Parts List For 10 DispensersMillennium Model MJ30-4 Optional Accessories DescriptionIMI Cornelius INC Illustrated Parts List Millennium II Illustrated Parts List NamePump Platform Assembly Lower Housing Assembly Refrigeration Deck Assembly 1717Illustrated Parts List Water Coil Assembly Pump & Motor Assembly Name Valve Panel Assembly Valve Block Assembly Name Touch Panel Assembly PB Touch Panel Assembly PC Name Electrical Box Assembly Name Ice Bank Control Assembly Name Brown Wire B4Speed Switch Assembly Name Top Panel Assembly Name Merchandiser Assembly Name Wiring For Volt 60 HZRecommended Spare Parts List Accessories and Service Items Illustrated Parts List Page N85318 Rev. B Print Date 2/99