Cornelius IWCS227, IAC 322, IAC227, CR800, CR1200 IAC 1230, IWC 1230 & IRC, IAC 1030, IWC 1030 & IRC

Page 63

 

 

LIQUID LINE

 

 

RD

 

 

 

 

RD

 

 

 

RD

 

 

 

SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GR

(R/C ONLY)

 

 

 

 

 

COMPRESSOR

COMPRESSOR

 

 

 

 

BK

 

 

 

 

 

 

RD

 

 

 

RUN

START

 

CONTACTOR

 

 

 

COMPRESSOR

 

 

 

 

CAPACITOR

CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

BR

 

 

 

RD

RD

 

 

 

 

 

 

R

 

SEE NOTE 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

S

YL

40 mfd

 

BK

 

 

BK

 

 

 

189-227 mfd

 

 

 

 

 

 

 

 

370 VAC

 

 

 

 

 

 

 

 

EXTERNAL

330 VAC

RD

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

COMPRESSOR

RD

 

 

 

 

 

 

 

 

 

M

 

 

 

OVERLOAD

 

 

 

 

RD

 

 

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

 

2

 

 

CRANKCASE

 

 

BK

CONDENSATION

POTENTIAL

5

 

 

 

 

 

 

 

HEATER

BL

 

 

1

 

 

 

 

FAN (W/C & R/C)

START RELAY

 

 

(RC ONLY)

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

MANUAL RESET

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

HIGH PRESSURE

 

 

 

 

 

 

CONTROL(W/C & R\C)

 

 

 

 

 

 

 

 

WATER DUMP

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CO

 

 

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

450 PSIG

BL

BK

 

 

 

WH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

WATER DUMP

CONDENSER

 

 

BR

 

BR

 

 

FAN MOTORS

 

 

 

 

 

 

SWITCH

 

 

 

 

 

3

2

 

(A/C ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

M

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

BK

 

BL

RH Evap.

Switch

N

S

LH Evap.

Switch

N

S

(White Lead)

Condenser Sensor

See note 1

Suction Line

Sensor

 

 

 

Water

 

 

D-15GR Dump

 

 

D-13

 

 

Valve

 

 

D-14

 

 

 

YL

 

 

 

 

GR

Relay

7

8

 

 

RH Evap.

 

 

 

5

6

 

 

GR

Water

3

4

D-10

 

Pump

 

 

1

2

YL

 

D-12

 

 

 

LH Evap.

 

D-11

Hot Gas

 

 

 

 

GR

 

 

 

 

Valve

230V

 

 

 

 

Condenser

 

 

Voltage

Plug

 

 

 

 

 

 

 

Selector

 

 

 

 

Suction

 

 

D-6

Condenser

Switch

 

 

 

Plug

 

 

GR

 

 

 

Fan

 

 

 

 

 

115V

 

 

 

 

 

M

BL

RD

RD

HOT GAS

SOLENOID

WH

WHWH

PUMP

CORD

(Brown Lead)

To Stacked

Unit

(if required)

Test

RD

Plug

D-5

 

Options

Error

 

Plug

Adjustable Ice

 

 

Thickness Pot.

Micro

Processor

Stacking

 

Cable

Manual

Plug

Harvest

 

Switch

Transformer

BL

M

WATER PUMP

 

IAC 1230, IWC 1230 & IRC 1230

BL

IAC 1030, IWC 1030 & IRC 1030

NOTE 1: CONDENSER SENSOR USED ONLY ON A/C UNITS. 1.8K ohm RESISTOR USED ONLY ON W/C & R/C UNITS.

2:CAPACITORS USED ON 1030 COMPRESSOR RUN CAP. 37MFD 370V

START CAP. 145 - 174 MFD 250V

12/1/94

60

166240004

Rev 3/4/96

 

 

Image 63
Contents Series Ice Cube Machine Table of Contents Table of Contents cont’d Model and Serial Location Series CuberSerial Number Explanation IAC322/330 IAC227 IWC322/330 Remote Condenser SpecificationICE Cuber Specification CR800 CR1200 CR1400LRA Specifications 60 HZIAC630 IWC630 IRC630 IAC830 IWC830 IRC830 IAC1030 IWC1030 IRC1030 IAC1030L IWC1030L IRC1030L IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448 Specifications 50 HZ Volts 220 Phase Hertz No. Wires +ground 220 12.5 75.9 CR800E50 CR1200E50 CR1400E50 Specifications 50 HZ, Remote CondenserGeneral Freight Damage Claims ProcedureEquipment SET-UP Installation InstructionsDispenser Installation Location of EquipmentIACS/IWCS Installation Check Points Plumbing ConnectionsElectrical START-UP and Check OUT Discard the ICE Cleaning ProceduresPrep Cleaning Owner -OPERATORDump Cycle Sanitizing ProceduresRH Evap Adjusting Bridge Thickness Total ICE CapacityICE Production Check LED Indicators Status Indicator Green Contactor Fan Dump Valve Circuit Board Diagnostic ProcedureMaking Adjustments Restoring ICE Thickness Potentiometer to Factory SettingSensors Reset OperationComponent Function Circuit Board ETC Test PlugThermostatic Expansion Valves Voltage Selector SwitchStacking Cable Condenser FAN Cycling ControlWater Regulating Valve Starving TXV Product SymptomsService Stem Valves Moisture ContaminationCompressor Contactor Relay Compressor & Starting Component CHECK-OUT ProcedureLeak Detection System Evacuation & RechargingSELF-CONTAINED Products Reclaim RecoveryAshrae RecyclingCompressor RUN-ON High Pressure Safety SwitchAverage Average Operating CharacteristicsIACS227/IAC322/IAC330 Freeze Cycle Harvest CycleIWCS227/IWC322/IWC330 IAC522/IAC530 IWC522/IWC530 IAC630 IWC630 IRC630 IAC830 IWC830 IRC830 IAC1030 IWC1030 IRC1030 IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448 Troubleshooting Compressor does not RUN, Circuit Board Indicator Lights onCuber not Operating Compressor Runs but Does not COOL, Circuit Board Indicator LightsProximity Switch Light OUT Proximity Switch Light onLong Harvest Cycles Long Freeze CycleWater Flow Associated GeneralPump not Pumping ICE Weight Light AT TOPPlate and Heavy AT Bottom Soft White ICE or Water aIAC 322 & IWC IAC 330 & IWC Water Dump Switch Condenser FAN Motor OnlyIacs 227 & Iwcs Volts 60 HZ IACS227E60, IWCS227E60 208/230V 60HZ IAC 530 & IWC IAC 522 & IWCIAC 630, IWC 630 & IRC IAC 830, IWC 830 & IRCIAC 1030, IWC 1030 & IRC IAC 1230, IWC 1230 & IRCIAC 1448, IWC 1448 & IRC CR800, CR1200, & CR1400 Remote Condensers Heat Shrink Tape CapacitorRefrigeration and Water Systems Refrigeration and water system Refrigeration and Water Systems Vavle Water Dump Valve Water Pump Refrigeration and Water System Remote Condenser Series Remote Ice Machine Installation Instructions Remote Condensers Liquid Refrigerant Line Discharge Correct Remote Condenser Location Physical Line-Set Length 55 Ft. Maximum 16.764 metersExamples Connection of Line-Set Lengthening or Reducing the Line-Set LengthsStart Up Final InstallationICE Cuber Specification Head Pressure Control Headmaster Evacuation Remote System EVACUATION/RE-CHARGEThis page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 763 800

IAC530, IWCS227, IWC522, IAC522, IAC330 specifications

Cornelius has established itself as a leader in the field of beverage dispensing systems, and its range of machines, including the IAC 322, IAC 227, CR800, CR1200, and CR1400, showcases advanced technology and user-friendly designs tailored for various commercial environments.

The Cornelius IAC 322 is a compact and versatile air-cooled unit designed for high-volume beverage dispensing. It features an efficient refrigeration system that ensures optimal temperature control, providing beverages that are always served at the perfect temperature. Its user-friendly interface allows operators to manage settings easily, and its durable construction ensures longevity in busy environments.

The IAC 227 model is similar in design but is specifically optimized for lower volume settings. With a smaller footprint, it is ideal for cafes and small bars. This model also incorporates energy-efficient technology, minimizing power consumption without compromising performance. The IAC 227 maintains the same commitment to temperature control, ensuring each cup served enhances the customer experience.

Turning to the CR series, the CR800 stands out with its robust build and larger capacity. This unit is designed for establishments needing a reliable dispenser for a variety of carbonated beverages. The CR800's carbonation technology ensures each drink maintains the right level of fizz, contributing to a consistent taste. Its modular design facilitates easy maintenance and upgrades, making it a favorite among operators.

The CR1200 increases capacity, making it suitable for larger venues, including stadiums and large restaurants. This model incorporates advanced monitoring systems that track beverage levels and alert operators when supplies are low. The CR1200 also supports multiple beverage types, allowing for customization based on customer preference while maintaining ease of use.

Lastly, the CR1400 takes it a step further, combining high-capacity dispensing with cutting-edge technology. It features touchscreen controls for intuitive operation and automated cleaning systems that reduce downtime. The CR1400 is designed with a focus on sustainability, using recyclable materials and energy-efficient components to lessen its environmental impact while maintaining premium performance.

Together, the Cornelius IAC and CR series models represent the forefront of beverage dispensing technology, emphasizing efficiency, durability, and customer satisfaction. Whether for a small café or a large arena, these machines provide businesses with the tools they need to serve quality beverages consistently.