Cornelius IWC330, IAC 322, IAC227, CR800, CR1200, CR1400, IWC530, IWC322, IAC330, IAC522, IWC522 IAC1030

Page 45

166240004

42

AVERAGE OPERATING CHARACTERISTICS

IAC1030

IP Units

 

 

 

FREEZE CYCLE

 

 

HARVEST CYCLE

 

AVERAGE

AVERAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAD

 

SUCTION

 

CYCLE

HEAD

 

SUCTION

 

CYCLE

AMBIENT

WATER

 

 

 

 

ICE

ICE

TEMP

TEMP

PRESSURE

 

PRESSURE

 

TIME

PRESSURE

 

PRESSURE

 

TIME

WEIGHT

WEIGHT

_F

_F

Psig

 

Psig

 

Min:Sec

Psig

 

Psig

 

Min:Sec

lb/Cycle

lb/Day

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

50

240

 

33

 

13:5

164

 

75

 

1:7

11.6

1101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

70

276

 

36

 

14:2

177

 

83

 

1.4

10.5

969

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

70

312

 

38

 

15:9

196

 

91

 

1:1

10.5

890

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

80

313

 

38

 

16:8

198

 

91

 

1:1

10.5

840

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

70

349

 

41

 

18:7

215

 

100

 

1:0

10.8

793

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SI Units

 

 

 

FREEZE CYCLE

 

 

HARVEST CYCLE

 

AVERAGE

AVERAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAD

 

SUCTION

 

CYCLE

HEAD

 

SUCTION

 

CYCLE

AMBIENT

WATER

 

 

 

 

ICE

ICE

TEMP

TEMP

PRESSURE

 

PRESSURE

 

TIME

PRESSURE

 

PRESSURE

 

TIME

WEIGHT

WEIGHT

_C

_C

kPa

 

kPa

 

Min:Sec

kPa

 

kPa

 

Min:Sec

kg/Cycle

kg/Day

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

10

1655

 

228

 

13:5

1131

 

517

 

1:7

5.3

499

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

21

1903

 

248

 

14:2

1220

 

572

 

1:4

4.8

440

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

21

2151

 

262

 

15:9

1351

 

627

 

1:1

4.8

404

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

27

2158

 

262

 

16:8

1365

 

627

 

1:1

4.7

381

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

21

2406

 

283

 

18:7

1482

 

689

 

1:0

4.9

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12/1/94 Rev 3/4/96

Image 45
Contents Series Ice Cube Machine Table of Contents Table of Contents cont’d Model and Serial Location Series CuberSerial Number Explanation ICE Cuber Specification Remote Condenser SpecificationCR800 CR1200 CR1400 IAC322/330 IAC227 IWC322/330LRA Specifications 60 HZIAC630 IWC630 IRC630 IAC830 IWC830 IRC830 IAC1030 IWC1030 IRC1030 IAC1030L IWC1030L IRC1030L IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448 Specifications 50 HZ Volts 220 Phase Hertz No. Wires +ground 220 12.5 75.9 CR800E50 CR1200E50 CR1400E50 Specifications 50 HZ, Remote CondenserGeneral Freight Damage Claims ProcedureDispenser Installation Installation InstructionsLocation of Equipment Equipment SET-UPIACS/IWCS Installation Check Points Plumbing ConnectionsElectrical START-UP and Check OUT Prep Cleaning Cleaning ProceduresOwner -OPERATOR Discard the ICEDump Cycle Sanitizing ProceduresRH Evap Adjusting Bridge Thickness Total ICE CapacityICE Production Check LED Indicators Status Indicator Green Contactor Fan Dump Valve Circuit Board Diagnostic ProcedureMaking Adjustments Restoring ICE Thickness Potentiometer to Factory SettingComponent Function Circuit Board ETC Reset OperationTest Plug SensorsStacking Cable Voltage Selector SwitchCondenser FAN Cycling Control Thermostatic Expansion ValvesWater Regulating Valve Starving TXV Product SymptomsService Stem Valves Moisture ContaminationCompressor Contactor Relay Compressor & Starting Component CHECK-OUT ProcedureLeak Detection System Evacuation & RechargingSELF-CONTAINED Products Ashrae RecoveryRecycling ReclaimCompressor RUN-ON High Pressure Safety SwitchIACS227/IAC322/IAC330 Average Operating CharacteristicsFreeze Cycle Harvest Cycle AverageIWCS227/IWC322/IWC330 IAC522/IAC530 IWC522/IWC530 IAC630 IWC630 IRC630 IAC830 IWC830 IRC830 IAC1030 IWC1030 IRC1030 IAC1230 IWC1230 IRC1230 IAC1448 IWC1448 IRC1448 Troubleshooting Compressor does not RUN, Circuit Board Indicator Lights onCuber not Operating Proximity Switch Light OUT Does not COOL, Circuit Board Indicator LightsProximity Switch Light on Compressor Runs butWater Flow Associated Long Freeze CycleGeneral Long Harvest CyclesPlate and Heavy AT Bottom ICE Weight Light AT TOPSoft White ICE or Water a Pump not PumpingIAC 322 & IWC IAC 330 & IWC Water Dump Switch Condenser FAN Motor OnlyIacs 227 & Iwcs Volts 60 HZ IACS227E60, IWCS227E60 208/230V 60HZ IAC 530 & IWC IAC 522 & IWCIAC 630, IWC 630 & IRC IAC 830, IWC 830 & IRCIAC 1030, IWC 1030 & IRC IAC 1230, IWC 1230 & IRCIAC 1448, IWC 1448 & IRC CR800, CR1200, & CR1400 Remote Condensers Heat Shrink Tape CapacitorRefrigeration and Water Systems Refrigeration and water system Refrigeration and Water Systems Vavle Water Dump Valve Water Pump Refrigeration and Water System Remote Condenser Series Remote Ice Machine Installation Instructions Remote Condensers Liquid Refrigerant Line Discharge Correct Remote Condenser Location Physical Line-Set Length 55 Ft. Maximum 16.764 metersExamples Connection of Line-Set Lengthening or Reducing the Line-Set LengthsStart Up Final InstallationICE Cuber Specification Head Pressure Control Headmaster Evacuation Remote System EVACUATION/RE-CHARGEThis page Left Blank Intentionally One Cornelius Place Anoka, Minnesota 763 800

IAC530, IWCS227, IWC522, IAC522, IAC330 specifications

Cornelius has established itself as a leader in the field of beverage dispensing systems, and its range of machines, including the IAC 322, IAC 227, CR800, CR1200, and CR1400, showcases advanced technology and user-friendly designs tailored for various commercial environments.

The Cornelius IAC 322 is a compact and versatile air-cooled unit designed for high-volume beverage dispensing. It features an efficient refrigeration system that ensures optimal temperature control, providing beverages that are always served at the perfect temperature. Its user-friendly interface allows operators to manage settings easily, and its durable construction ensures longevity in busy environments.

The IAC 227 model is similar in design but is specifically optimized for lower volume settings. With a smaller footprint, it is ideal for cafes and small bars. This model also incorporates energy-efficient technology, minimizing power consumption without compromising performance. The IAC 227 maintains the same commitment to temperature control, ensuring each cup served enhances the customer experience.

Turning to the CR series, the CR800 stands out with its robust build and larger capacity. This unit is designed for establishments needing a reliable dispenser for a variety of carbonated beverages. The CR800's carbonation technology ensures each drink maintains the right level of fizz, contributing to a consistent taste. Its modular design facilitates easy maintenance and upgrades, making it a favorite among operators.

The CR1200 increases capacity, making it suitable for larger venues, including stadiums and large restaurants. This model incorporates advanced monitoring systems that track beverage levels and alert operators when supplies are low. The CR1200 also supports multiple beverage types, allowing for customization based on customer preference while maintaining ease of use.

Lastly, the CR1400 takes it a step further, combining high-capacity dispensing with cutting-edge technology. It features touchscreen controls for intuitive operation and automated cleaning systems that reduce downtime. The CR1400 is designed with a focus on sustainability, using recyclable materials and energy-efficient components to lessen its environmental impact while maintaining premium performance.

Together, the Cornelius IAC and CR series models represent the forefront of beverage dispensing technology, emphasizing efficiency, durability, and customer satisfaction. Whether for a small café or a large arena, these machines provide businesses with the tools they need to serve quality beverages consistently.