Cornelius SID650A/80-BC, SID650W/80-BC manual 91704

Page 22

1. TOTALLY INOPERATIVE

YES

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE INSIDE UNIT.

IS LINE

NOVOLTAGE

WITHIN ￿ 10% OF

NAMEPLATE

VOLTAGE?

YES

1.CHECK FOR SHORT CIRCUIT IN WIRING INSIDE UNIT.

2.CHECK COMPONENTS FOR SHORT CIRCUIT OR GROUNDED WIRING.

IS

LINE VOLTAGE

HIGH OR

LOW?

POWER

PRESENT ATNO

REAR JUNCTION

BOX?

IS

YESSUPPLY FUSE

BLOWN (OR C/B

TRIPPED)?

NO

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE IN SUPPLY

WIRING OF UNIT.

IS

YESFUSE OR C/B

SIZE PROPER?

NO

REPLACE WITH CORRECT

SIZE DEVICE.

LOW

HIGH

INSTALL BUCKING TRANSFORMER

TO REDUCE LINE VOLTAGE.

IS

YESOTHER EQUIP. ON SAME CIRCUIT?

NO

1.REMOVE ALL OTHER EQUIPMENT FROM ICE MAKER CIRCUIT.

2.INSTALL NEW DEDICATED CIRCUIT FOR ICE MAKER.

1.CHECK FOR LOOSE OR CORRODED CON- NECTION IN SUPPLY WIRING.

2.CHECK SUPPLY WIRING FOR UNDER- SIZED WIRE, AND REPLACE.

3.INSTALL BOOSTING TRANSFORMER TO RAISE LINE VOLTAGE.

19

91704

Image 22
Contents Spiral Icemaker Dispenser Table of Contents Table of Contents cont’d General Information DescriptionInstallation Instructions Installation InstructionsUnpacking Instructions Electrical Wiring Installation Instructions Installations Dimensions Mounting Template Model SID650-80 Beverage System START-UPBeverage System Schematic B Models Beverage System Schematic BC Models Harvest Cycle Time Cam Switch Action Operating InstructionsWiring Schematic Wiring Diagram Refrigeration Schematic Maintenance Cleaning InstructionsDispenser Section For Units with Beverage System Cold Plate 91704 Troubleshooting Guide 91704 91704 Is ICE Production ICE Maker Problem YES RUN RUN/STOP Stop Hopper YES Present AT No ICE on Evaporator Harvest YES 10%? Adjust ICE Thickness Probe only After ALL OTH LOW ICE Production 91704 Dispenser Problem YES Does 91704 MAINTENANCE/ADJUSTMENT Procedures BIN ThermostatCLEANING/REPLACE the Filter Harvest Time Adjustment Distributed By Commercial Refrigeration Service, Inc Parts List Description Part NumbersParts List CONT’D Air Cooled Water Cooled Refrigeration Components 80 BCWarranty Remcor Incorporated Regency Drive Glendale Heights, IL 708