2.B COMPRESSOR INOPERATIVE

IS

LINE VOLTAGE

YESWITHIN ￿ 10%

OF NAMEPLATE

VOLTAGE?

IS

THERMALNO PROTECTOR

OPEN?

YES

NO

IS

CONTACTOR

PULLED

IN?

NO

CHECK VOLTAGE PROBLEMS IN 1 .

YES

 

 

 

IS

 

YES

COMPRESSOR

NO

 

 

 

BODY

 

 

 

 

COLD?

 

 

 

 

 

 

 

 

 

 

REPLACE

 

 

 

 

 

THERMAL

 

 

 

 

 

PROTECTOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

1.CHECK FOR LOOSE OR BROKEN WIRING CONNECTION IN COMPRESSOR POWER CIRCUIT.

2.CHECK CONTACTOR.

3.CHECK STARTING RELAY.

4.CHECK CAPACITOR(S).

5.CHECK COMPRESSOR MOTOR.

 

IS

 

 

120V.

 

YES

PRESENT AT

NO

 

CONTACTOR

 

 

COIL

 

 

TERMINAL?

 

REPLACE CONTACTOR.

1.CHECK FOR LOOSE OR BROKEN WIRING CONNECTION IN CONTROL CIRCUIT.

2.GO TO 2.A

91704

22

Image 25
Contents Spiral Icemaker Dispenser Table of Contents Table of Contents cont’d Description General InformationInstallation Instructions Installation InstructionsUnpacking Instructions Electrical Wiring Installation Instructions Installations Dimensions Mounting Template Model SID650-80 START-UP Beverage SystemBeverage System Schematic B Models Beverage System Schematic BC Models Operating Instructions Harvest Cycle Time Cam Switch ActionWiring Schematic Wiring Diagram Refrigeration Schematic Cleaning Instructions MaintenanceDispenser Section Cold Plate For Units with Beverage System91704 Troubleshooting Guide 91704 91704 Is ICE Production ICE Maker Problem YES RUN RUN/STOP Stop Hopper YES Present AT No ICE on Evaporator Harvest YES 10%? Adjust ICE Thickness Probe only After ALL OTH LOW ICE Production 91704 Dispenser Problem YES Does 91704 BIN Thermostat MAINTENANCE/ADJUSTMENT ProceduresCLEANING/REPLACE the Filter Harvest Time Adjustment Distributed By Commercial Refrigeration Service, Inc Description Part Numbers Parts ListAir Cooled Water Cooled Refrigeration Components 80 BC Parts List CONT’DWarranty Remcor Incorporated Regency Drive Glendale Heights, IL 708