IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of
For specific recommendations on these filter systems for your local conditions, consult with a distributor in your area or contact the filter manufacturer.
Connect two (2) 3/4 IPS (or equal) drain lines to the 3/4 threaded drain connections at the lower rear of the unit. These lines must pitch downward to an open drain and must contain no traps or improper drainage
will result.
NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre- Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor for more information on this product.
3.Electrical
A 4 x 2 junction box is located at the rear of the unit for the supply
IMPORTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be within a range of ± 10% for proper ice maker operation.
NOTE: The units require a 2 wire system plus earth ground for proper operations.
BROWN (HOT)
BLUE (NEUTRAL)
SUPPLY CONDUIT
220V
1 PHASEGREEN (GROUND)
60 HERTZ
REAR VIEW
FIGURE 1. ELECTRICAL WIRING INSTALLATION INSTRUCTIONS