INITIAL START UP, CHECKS AND ADJUSTMENT INSTRUCTIONS
NOTE: Do not start Icemaker before completing installation steps on pages 7 and 9.
Turn on water supply (if Icemaker is water cooled turn water on to condenser also) turn on main power switch (located on top of electrical box), and make the following system checks:
NOTE: If Icemaker will not start be sure water reservoir is full. Low water safety control must be prop- erly adjusted to start and shut down the Icemaker. If water level drops below bottom of reservoir, the Icemaker must shut down. Adjustment is made by moving magnet up or down.
Water
Low Water Safety
Bin
NOTE: For altitudes over 1000 feet above sea level, adjust range screw (behind end cover). Half turn max. raises setting 4_F approx.
FIGURE 3. ICEMAKER FLOAT ASSEMBLY
Water modulating valve (water cooled units
9 | 630460150 |