Cornelius UC 701 service manual Electrical Checkout, Capacitor Check

Page 22

3.Remove Dispense Tray Cover.

4.Use an open end wrench on auger nut connected to bearing and turn counterclockwise to remove assembly.

5.Remove worn bearings. Replace with new bearings and then reinstall assembly.

NOTE: If auger turns with nut, remove cover on top of gearmotor stator and hold motor while loosen- ing nut.

FIGURE 10. OVERLOAD CHECK

FIGURE 11. COMPRESSOR CHECK

ELECTRICAL CHECKOUT

1.Be sure the unit is disconnected from the power source. Remove the compressor electrical box cover. Check for obvious damage and loose wires.

2.Disconnect the fan motor leads. Since capacitors store energy, short the capacitor with a screwdriver. This will prevent shocks.

3.Disconnect the compressor terminal wires.

OVERLOAD CHECK (See Figure 10)

1.Using a volt-ohmmeter check the continuity across the overload, contact #1 and #3. If none, wait for unit to cool down and try again. If still no continuity, the overload protector is defective and should be replaced.

COMPRESSOR CHECK (See Figure 11)

The resistance readings on the windings will be between 0.25 to 10.00 ohms, a meter capable of these low readings must be used.

1.Check between “C” and “R.” Replace the compressor if there is no continuity as the run windings are open.

2.Check between “C” and “S.” Replace the compressor if there is no continuity as the start windings are open.

3.Check between “C” and “R” or “S” and the shell of the compressor. If there is continuity, replace the com- pressor as the motor is grounded.

4.Check between screw terminal on the overload and “C” on the compressor. Check and repair the lead or connections if there is no continuity.

CAPACITOR CHECK

1.Check or replace start capacitor, disconnect bleed resistor before checking for shorted capacitor.

2.Check or replace run capacitor (if supplied) check for shorted capacitor or either terminal grounded to case.

19

630460150

Image 22
Contents UC 701 Series CONTINUOUS-FLOW Icemaker Table of Contents Table of Contents cont’d Understand Signal Words Safety InformationRecognize Safety Information Follow Safety InstructionsThis page Left Blank Intentionally Description General DescriptionTo the User of this Manual Claims InstructionsSpecification Chart Clearance Requirements This page Left Blank Intentionally Installation PRE-INSTALLATIONInstallation Side Bracket InstallationInitial Start UP, Checks and Adjustment Instructions Icemaker Float AssemblyThis page Left Blank Intentionally Maintenance Guide to ServiceIcemaker Cleaning and Sanitizing Procedures MonthlyHow Water Level Control Works Water Level ControlSemi-Annually PurposeRefrigeration System Refrigeration System AdjustmentsTo Replace Water Level Safety Switch To Replace Water Level ControlExpansion Valve Adjustment and TroubleshootingCondenser Modulating Valve Condenser Modulating Valve Removal BIN ControlGearmotor Motor CheckTo Replace Gearmotor Assembly Start RelayAuger and Extruding Head Removal Upper NUT and Bearing AssemblyTo Replace Bearing Electrical Checkout Capacitor CheckSafety Controls Gear Motor OverloadGuide to Good ICE Wiring Diagram Troubleshooting Chart Icemaker not Operating Troubleshooting Troubleshooting CompressorsCertificate of Warranty IMI CorneliusThis page Left Blank Intentionally IMI Cornelius INC