7.The Paging output is limited to a nominal 70 Volts rms by the ALC. In a properly designed system, sound loudness is normally adjusted by selection of appropriate speakers and their individual tap settings for a 70 Volt input. However, circumstances such as a long term change in ambient noise may call for reducing the loudness of all speakers en-mass. This output level can be attenuated by an overall AmpliCenter output level control setting. This setting is accomplished remotely from any host system phone that dials DTMF.

Dial the paging access code.

When you have cut-thru, dial [#] [#] [#] [#] followed by:

DTMF digit

Output Attenuation

8

0 dB

7

–3 dB

6

–6 dB

5

–9 dB

4

–12 dB

3

–15 dB

2

–18 dB

1

–21 dB

NOTES:

When used, the PagePac Plus Controller must be configured to pass DTMF signals to that zone in order for this to work. Also, MERLIN multi-button sets require pressing [#] twice for every # sent; therefore a string of eight [#] s must be pressed before the level setting digit is registered.

The DTMF tones will be heard from the loudspeakers during this adjustment.

The setting is retained in the Controller memory during power black-outs for 24 hours minimum, 1 week typical.

The maximum AmpliCenter power rating is reduced by the attenuation level; i.e. total speaker load impedance may not be less than 250 ohms for the D20, 50 ohms for the D100, or 16.7 ohms for the D300.

The 0dBm output is also attenuated proportionally to the 70V output.

8.Adjust Music Ducking level. This feature allows music to continue to be heard during a Page, but at a reduced level. The range is from less than -40dB (full CCW) to -6 dB (full CW).

3-14Installing the Hardware

Image 35
Contents PagePac Plus AmpliCenter Trademarks Overview N t e n t sInstalling the Hardware B l es Controls and Indicators, Terminals and ConnectorsFigures Overview ContentsBefore You Start How to Use This GuideAbout This Guide Installation Steps Installation StepsPagePac Plus Connectivity Chart Connectivity ChartLoop 600 Ω PagePac Plus Connectivity Chart ContinuationReference Materials Product Safety LabelsHow to Comment on This Guide TerminologyShipping Container Contents Ordering Information PagePac Plus AmpliCenter Features and CapabilitiesAmpliCenter Specifications SpecificationsHardware Configuration Mounting PowerCircuit Protection Universal Approvals Controls and Indicators, Terminals and ConnectorsControls and Indicators, Terminals and Connectors Auxiliary Equipment Installing the Hardware Additional Safety Instructions for Installation Personnel Important Safety InformationAmpliCenter without Controller, with Series AmpliCenters Example System Setup Amplicenter Interface with ControllerController Series AmpliCenters, without Controller Tools Required Mounting PagePac Plus AmpliCenterFront Detail Speaker Run Method Connecting SpeakersTelephone System Interface Telephone Mode Switch10Installing the Hardware Connection to AmpliCenter Music Input Connections Music Source InterfaceAudio Paging Zones System TestingApply AC Power Dtmf digit Maintenance and Customer Support Case of Difficulty Troubleshooting Power Failure OperationCommon Problems Answer TroubleshootingAmpliCenter Electrical Block Digram Electrical Block DiagramFCC Statement Part Radio Frequency Interference FCC Statement and Warranty Information2FCC Statement and Warranty Information Installation and Maintenance Information Feedback Form How are we doing? FCC D exRack mounted hardware Diagram AT&T