The following items describe all control and indicator functions illustrated in figure
Table 2-1. Controls and Indicators, Terminals and Connectors
1.AC Power in:
2.0dBm out, an auxiliary output that differs from the main 70.7V output in that it is a low level (0dB), 600 ohm balanced output used for driving a remote or
3.DC Power, and 70V audio out to Controller
4.Bass control
5.Music In: left and/or right channels with ground;
Paging In: redundant paging input (ground, C1, tip, and ring)
70V Out: Balanced output used for terminating the loudspeaker wiring
6.
7.LEDs: green - power on, lights when AC line voltage is applied to AmpliCenter
red – overload, lights when the AmpliCenter output exceeds its output power rating.
This can occur when total speaker load is greater than the output rating, or when speaker wiring is shorted
red - unbalanced output, indicates when one speaker lead is accidentally shorted to ground green – page accessed, lights when voice paging is active
8.Telephone system mode switch: dry loop 600 ohms, dry loop Hi Z, ground start, and loop start
9.From host telephone system or Controller RJ11 connector paging audio and control