Emergency treatment:
The battery is constructed maintenance free and leakproof. It is well
protected in Jiva system as long as the ambient temperature remains below
30°C and the ventilation of the Jiva system remains free. However, should any
accident happen and the sulfuric acid from the battery spills on skin or clothing,
wash immediately with water. If the acid comes in contact with eyes, rinse
eyes with large amount of clean water and see a doctor immediately. A larger
external battery may be connected to give an extended operation. Please check
your dealer about this capability when required.
WARNING:
If there are any signs of over charging or leakage of electrolyte
please contact your dealer immediately
Power Supply
The operating voltage range of the power adaptor should cover the
local power supply for proper operation. The power cable, the power outlet
and any power fusing arrangements must conform to local safety regulations.
Please never do any connection / disconnection when system is still
powered on. Please always keep the external power adaptor in a free air
circulation.
POWER ON/OFF
There must always be at least 10 seconds waiting before switching on
again once the system is powered off successfully.
LED Indicator
There is an LED in the logo area or under the printed logo and serves
for several purposes. The relationship between LED status and other
conditions is summarized in following table:
LED Status
System Status
External Power
UPS Battery
Powering Up
Off Off Off Not present
Not possible
Off Off Off Present Not allowed
Green Off On No influence
Allowed
Blue On On No influence
Not required
Blue/flash On Off Activated Not required
Green/rapid
flash On Off Running at
low capacity
Not required