Part 14
USING THE TOUCH POS

APPLICATION ENVIRONMENT

It is very important that you check the following operation guidelines:
Ventilation
This terminal must NOT be operated in an environment with
restricted ventilation. The installation should be such that there is at least
25mm air clearance around any top or side ventilation holes. The installation
must also be such that there is a free flow of air around the unit at ALL times.
Operating Environment
The equipment must not be operated or stored in extremes of both
temperature and humidity/moisture. (Operating range 5°C to 35°C and up to
80% humidity non condensing)
UPS Battery (option)
General care:
The UPS battery is consumables beyond product warranty. Please
definitely observe the alerts in beginning of this manual. If the equipment is to
be powered off for more than few days , please always disconnect the battery
from the system. Reconnect it and turn on the system to recharge the battery
for 1 ~ 2 hours every 3 months for temperature lower than 30°C. Recharge for
1 ~ 2 hours every month for temperature over 30°C. Temperature above 40°C
must be strictly avoided as it could cause termination of battery life and
unexpected result even if the battery is not in work. The UPS battery can
support basically the data preservation and smooth running of the system
during intermittent or few minutes (3 ~ 8 min. depending on loading and
battery condition) power failure.
Battery replacement:
In the preloaded OS for a Jiva 5800 series, there is a built in utility
Power Manager that will interface the UPS battery monitor status with user.
When battery monitor disables the battery charging as designed while the UPS
function of the system is originally enabled, in other words the UPS battery is
found out of order if actually installed, there will be a popup message as the
picture at right asking the user to agree disabling the
UPS function. The system will operate under
deactivated UPS function no matter agreed or not.
However, the monitoring goes on and the popup
message will come back on next system power up boot if not agreed. In any
case, please replace the used up UPS battery at power off if the battery is well
connected there but found inoperable by such messages.