Overload Protections

The compressor overload and start protection cuts off power to the compressor if the compressor speed drops below approximately 1,900 rpm, or if this motor speed is not reached during the start sequence. Possible reasons for overload protection activating could be too high refrigeration system pressures during operation or lack of pressure equalizing at start.

The fan overload protection stops the compressor if the fan current exceeds 0.5 A (avg) or 1 A (peak).

An overheating of the electronic unit heat sink will cause the compressor to stop. Restart will occur automatically when a normal temperature has been reached. If a fan is installed, it will continue to run when the compressor stops due to overload or electronic unit overheating.

Voltage Protection

If a voltage outside any concerned range is applied to the electonic unit, the compressor does not start, or it stops if the voltage limit is exceeded during operation. The compressor will restart automatically approximately 1 minute after the supply voltage has reached the reset voltage within the range in question.

Battery protection

The Danfoss electronic unit provides protection as follows:

Standared Battery Protection Settings

12V cut-out

12V cut-in

10.4

11.7

Final Installation Notes

For all appliances, AVOID the use of any electrical adapters or extension cords.

After installation, allow the appliance to sit for at least one hour before starting.

The manufacturer assumes no responsibility for any injuries or damage caused by noncompliance with any of the installation regulations.

DOMETIC CORPORATION, ENVIRONMENTAL DIVISION

 

P.O. Box 15299 I Richmond, VA 23227 USA

 

Phone +804 746 1313 Fax +804 746 7248

 

www.dometic.com

Page 12 of 20

Image 12
Contents For 750000005 TJ18F 750000011 TJ22F 750000026 TJ18FP3 Refrigerator ComponentsTROUBLE-SHOOTING Example the Dataplate above has a serial numberAppliance Does Not Operate. Check See Wiring Diagram in the later sections 750000005 TJ18F 750000011 TJ22F 750000026 TJ18FP3Speed Resistor Freightliner Refrigerator Troubleshooting Guide Freightliner Refrigerator Troubleshooting Guide Freightliner Refrigerator Troubleshooting Guide Check incoming voltage Checking the CompressorChecking the Fan DC Wiring Danfoss Compressor Data Voltage RangeProtection Systems Battery protection Final Installation NotesVoltage Protection 750000005 TJ18F 750000011 TJ22F 750000026 TJ18FP3 Freightliner Refrigerator Troubleshooting Guide Freightliner Refrigerator Troubleshooting Guide Service Part Description This drawing illustrates model TJ22F 135 3312372.000 Harness KIT, Freightliner Freightliner Refrigerator Troubleshooting Guide Freightliner Refrigerator Troubleshooting Guide