If Ice Maker Is Currently Installed
NOTE: If ice maker is not installed, please proceed to “Drain Pump Installation” section.
1.Push the selector switch to the Off position.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
2.Unplug ice maker or disconnect power.
3.Turn off water supply. Wait 5 to 10 minutes for the ice to fall into the storage bin. Remove all ice from bin.
4.Unscrew the drain cap from the bottom of the water pan located inside the storage bin. Allow water to drain completely. Replace drain cap. See “Drain Cap” illustration.
Drain Cap
A
A. Drain cap
5.If ice maker is built into cabinets, pull ice maker out of the opening.
6.Disconnect water supply line. See “Water Supply Line” illustration.
Water Supply Line
| A |
|
| B | B |
|
| |
|
| C |
|
| D |
| C |
|
| E |
|
A. ¹⁄₄" copper tubing | D. Ferrule (sleeve) |
|
B. Cable clamp | E. Ice maker connection |
|
C. ¹⁄₄" compression nut |
|
|
Drain Pump Installation
NOTE: Do not kink, smash or damage tubes or wires during installation.
1.Unplug ice maker or disconnect power.
2.Remove rear panel. See “Rear Panel” illustration for 5 screw locations. Pull rear panel away from the drain tube and discard.
Rear Panel
A
A
A. Screw locations
3.Remove the old drain tube and clamp attached to the ice maker bin.
NOTE: Discard old drain tube and clamp.
4.Install new drain tube (⁵⁄₈" ID x 5¹⁄₈") from ice maker bin to drain pump reservoir inlet using new adjustable clamps. See “Drain Tube” illustration.
NOTES:
■Do not kink.
■Trim tube length, if required.
Drain Tube
| A |
| B |
| C |
| D |
A. ⁷⁄₈" adjustable hose clamp | C. ⁷⁄₈" adjustable hose clamp |
B. Drain tube (ice bin to drain pump) | D. Drain pump reservoir inlet |
5.Install vent tube (⁵⁄₁₆" ID x 32" [81 cm]) to drain pump reservoir vent. Use one ⁵⁄₈" small adjustable clamp, supplied. See “Parts Locations” illustration.
NOTE: Do not install household drain tube at this time.
5