Whirlpool W10541636B important safety instructions Drain Pump Mounting Tab Slot, Vent Tube

Page 6

Parts Locations

Drain Pump Installed

 

A

 

B

 

C

 

D

 

A

 

E

G

F

A. Vent tube

E. Ice maker unit power cord

B. ⁵⁄₈" hose clamp

F. #8-32 x ³⁄₈" pump mounting screws

C. Drain pump discharge tube

G. Drain pump power cord, clamp

D. Drain pump

and screw

6.Remove power cord clamp and ground screw attached to ice maker power cord, which is mounted to the unit base. See “Parts Locations” illustration.

NOTE: Clamp and screw will be reused.

7.Slide drain pump into the ice maker base on the right side. The pump mounting tab should slip into the rectangular slot in the ice maker base. It will be necessary to tip the pump slightly to slip into the slot. See “Drain Pump Mounting Tab Slot” illustration.

Drain Pump Mounting Tab Slot

A

A. Mounting tab slot

A. Drain pump installed

8.Align the 2 screw holes at the rear of the pump. Use two #8-32 x ³⁄₈" screws, supplied. See “Parts Locations” illustration.

9.Connect drain tube to ice maker bin outlet (⁵⁄₈" ID), using ⁷⁄₈" adjustable clamp, supplied. See “Drain Tube” illustration.

10.Coil ice maker power cord into a 4" (10.2 cm) diameter coil. Wrap electrical tape around the power cord in several places to keep the cord in a coil. Locate coiled power cord between the drain pump and side of enclosure and plug into the receptacle of the drain pump. See “Parts Locations” illustration.

11.Attach the drain pump power cord to ice maker unit base with clamp and screw (removed in Step 6) that was used to attach ice maker power cord. See “Parts Locations” illustration.

12.Place new rear panel (small one for 15" ice makers, large one for 18") against the back of the ice maker. Route the vent tube and drain pump discharge tube through cutouts in the rear panel.

13.Secure rear panel with original screws. See “Rear Panel” illustration.

14.Secure vent tube to back of ice maker using 3 clamps and three #8-32 x ³⁄₈" screws, supplied. See “Vent Tube” illustration.

Vent Tube

NOTE: Do not pinch, kink or damage the vent tube. Check that it is not damaged, or pinched or kinked between the cabinet and the ice maker.

A

B

A. Vent tube

B. Clamps and screws

6

Image 6
Contents ICE Maker Safety Table of Contents/Table des matièresUnpack the Ice Maker Installation InstructionsCleaning Before Use Location RequirementsVacation or Extended Time Without Use Electrical RequirementsWater Supply Requirements Connect Water SupplyIce Maker Drain Pump Installation Rear ViewKit Contains Drain Cap If Ice Maker Is Currently InstalledDrain Pump Installation Water Supply LineDrain Pump Mounting Tab Slot Vent TubeSide View Drain ConnectionGravity Drain System Drain Pump System on some modelsOn Some Models Connecting the DrainIce Maker Door Reversal-Side Swing Only Door Stop and End-Cap ReversalOn Some Models-Replace Door Wrap Reverse HingesReplace Door Top HingeCleaning LevelingInterior Components On Some Models Sécurité DE LA Machine À Glaçons Votre sécurité et celle des autres est très importanteDéballage de la machine à glaçons Instructions D’INSTALLATIONExigences d’emplacement Spécifications électriquesSpécifications de l’alimentation en eau Vacances ou longue période d’inutilisationRaccordement à la canalisation d’eau Installation de la pompe de vidange de la Machine à glaçons Vue arrièreContenu de l’ensemble Bouchon de vidange Si la machine à glaçons est installéeInstallation de la pompe de vidange Canalisation d’alimentation en eauTube de vidange Position des piècesVidange par gravité Raccordement au drain de vidangeTube de ventilation Vue latéraleSystème avec pompe de vidange sur certains modèles Raccordement du drain de vidangeInversion du sens de montage des charnières Réinstallation de la porteSur certains modèles Réinstallation du revêtement de porte Charnière supérieureInversion du sens dinstallation de la gâche de porte NivellementCharnière inférieure Nettoyage Composants intérieursSur certains modèles Imprimé aux É.-U