Parts Locations | Drain Pump Installed |
| A |
| B |
| C |
| D |
| A |
| E |
G | F |
A. Vent tube | E. Ice maker unit power cord |
B. ⁵⁄₈" hose clamp | F. |
C. Drain pump discharge tube | G. Drain pump power cord, clamp |
D. Drain pump | and screw |
6.Remove power cord clamp and ground screw attached to ice maker power cord, which is mounted to the unit base. See “Parts Locations” illustration.
NOTE: Clamp and screw will be reused.
7.Slide drain pump into the ice maker base on the right side. The pump mounting tab should slip into the rectangular slot in the ice maker base. It will be necessary to tip the pump slightly to slip into the slot. See “Drain Pump Mounting Tab Slot” illustration.
Drain Pump Mounting Tab Slot
A
A. Mounting tab slot
A. Drain pump installed
8.Align the 2 screw holes at the rear of the pump. Use two
9.Connect drain tube to ice maker bin outlet (⁵⁄₈" ID), using ⁷⁄₈" adjustable clamp, supplied. See “Drain Tube” illustration.
10.Coil ice maker power cord into a 4" (10.2 cm) diameter coil. Wrap electrical tape around the power cord in several places to keep the cord in a coil. Locate coiled power cord between the drain pump and side of enclosure and plug into the receptacle of the drain pump. See “Parts Locations” illustration.
11.Attach the drain pump power cord to ice maker unit base with clamp and screw (removed in Step 6) that was used to attach ice maker power cord. See “Parts Locations” illustration.
12.Place new rear panel (small one for 15" ice makers, large one for 18") against the back of the ice maker. Route the vent tube and drain pump discharge tube through cutouts in the rear panel.
13.Secure rear panel with original screws. See “Rear Panel” illustration.
14.Secure vent tube to back of ice maker using 3 clamps and three
Vent Tube
NOTE: Do not pinch, kink or damage the vent tube. Check that it is not damaged, or pinched or kinked between the cabinet and the ice maker.
A
B
A. Vent tube
B. Clamps and screws
6