Base Grille Water Filtration System
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class II*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Benzene, Toxaphene,
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Model WF-NL240V/NL240V Capacity 240 Gallons (908 Liters)
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 2.0 mg/L | 2.0 mg/L ± 10% | 0.03 mg/L | 0.02 mg/L | 98.5% | 99.0% | |
Particulate Class II* | ≥85% | 833,333/mL | At least 10,000 | 100,000/mL** | 40,667/mL | 88.0% | 95.1% | |
|
|
| particles/ml |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge Maximum | Average | Minimum % | Average % | NSF Test | |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01mg/L | 0.16 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.35% | 99.35% | |
Lead: @ pH 8.5 | 0.01mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.31% | 99.31% | |
|
|
|
|
|
|
|
|
|
Mercury: @ pH 6.5 | 0.003 mg/L | 0.0062 mg/L | 0.006 mg/L ± 10% | 0.0003 mg/L | 0.00023 mg/L | 95.2% | 96.8% | |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0061 mg/L | 0.006 mg/L ± 10% | 0.0009 mg/L | 0.00052 mg/L | 85.2% | 91.8% | |
|
|
|
|
|
|
|
|
|
Benzene | 0.005 mg/L | 0.014 mg/L | 0.015 ± 10% | 0.0005 mg/L | 0.0005 mg/L | 96.4% | 96.4% | |
|
|
|
|
|
|
|
|
|
0.075 mg/L | 0.219 mg/L | 0.225 ± 10% | 0.0005 mg/L | 0.0005 mg/L | 99.77% | 99.77% | ||
|
|
|
|
|
|
|
|
|
Toxaphene | 0.003 mg/L | 0.014 mg/L | 0.015 ± 10% | 0.0012 mg/L | 0.001 mg/L | 91.43% | 92.6% | |
|
|
|
|
|
|
|
|
|
Carbofuran | 0.04 mg/L | 0.077 mg/L | 0.080 ± 10% | 0.031 mg/L | 0.0064 mg/L | 59.7 % | 91.6% | |
|
|
|
|
|
|
|
|
|
Model WF-L400V/L400V Capacity 400 Gallons (1514 Liters)
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Aesthetic Effects | Requirement | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 2.0 mg/L | 2.0 mg/L ± 10% | 0.03 mg/L | 0.02 mg/L | 98.5% | 99.0% | |
Particulate Class II* | ≥85% | 833,333/mL | At least 10,000 | 100,000/mL** | 40,667/mL | 90.9% | 95.1% | |
|
|
| particles/ml |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % | NSF Test |
Reduction | Requirement | Influent | Concentration | Effluent | Effluent | Reduction | Reduction | Number |
|
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01mg/L | 0.16 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.35% | 99.35% | |
Lead: @ pH 8.5 | 0.01mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.31% | 99.31% | |
|
|
|
|
|
|
|
|
|
Mercury: @ pH 6.5 | 0.003 mg/L | 0.0062 mg/L | 0.006 mg/L ± 10% | 0.0003 mg/L | 0.00023 mg/L | 95.2% | 96.22% | |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.0061 mg/L | 0.006 mg/L ± 10% | 0.0009 mg/L | 0.00052 mg/L | 85.2% | 91.57% | |
|
|
|
|
|
|
|
|
|
Benzene | 0.005 mg/L | 0.014 | 0.015 ± 10% | 0.005 mg/L | 0.0005 | 96.4% | 96.4% | |
|
|
|
|
|
|
|
|
|
0.075 mg/L | 0.219 | 0.225 ± 10% | 0.0005 mg/L | 0.0005 | 99.77% | 99.77% | ||
|
|
|
|
|
|
|
|
|
Toxaphene | 0.003 mg/L | 0.014 | 0.015 ± 10% | 0.0012 mg/L | 0.001 | 91.43% | 92.86% | |
|
|
|
|
|
|
|
|
|
Carbofuran | 0.04 mg/L | 0.0768 | 0.080 ± 10% | 0.031 mg/L | 0.0057 | 59.7 % | 92.5% | |
|
|
|
|
|
|
|
|
|
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
■Model
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the front cover or “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8° C) |
Service Flow Rate | 0.5 gpm (1.9 L/min.) @ 60 psi. |
*Class II particle size: >1 to <5
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International.
12