PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model
Model
Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class II*; and against ANSI/NSF Standard 53 for the reduction of Lead.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Chlorine Taste/Odor | ≥50% | 1.9 mg/L | 2.0 mg/L ± 10% | 0.05 mg/L | 0.05 mg/L | 97.4% | 97.4% |
Particulate Class II* | ≥85% | 833,333/mL | At least 10,000 | 100,000/mL** | 40,667/mL | 88.0% | 95.1% |
|
|
| particles/mL |
|
|
|
|
|
|
|
|
|
|
|
|
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
|
|
|
|
|
|
|
|
Lead: @ pH 6.5 | 0.01 mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.001 mg/L | 0.001 mg/L | 99.3% | 99.3% |
Lead: @ pH 8.5 | 0.01 mg/L | 0.15 mg/L*** | 0.15 mg/L ± 10% | 0.003 mg/L | 0.001 mg/L | 97.9% | 99.0% |
|
|
|
|
|
|
|
|
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Model
2006 suggested retail price of $32.99 U.S.A./$44.95 Canada. Prices are subject to change without notice.
Model
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the front cover or “Assistance or Service” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8°C) |
Service Flow Rate | 0.5 gpm (1.9 Lpm) @ 60 psi. |
|
|
*Class II particle size: >1 to <5
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International.
11