3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.
1.Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
A
B
C
D
A. Terminal block
B.
C.Cord/conduit plate
D.Power supply cord wires
2.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the
A | E |
|
B | D |
| |
C |
|
A. | D. Neutral (white) wire |
B. Line 1 (black) | E. Line 2 (red) |
C.
3.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with
4.Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.
5.Replace terminal block access cover.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required
1.Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulation back 1" (2.5 cm) from the end of each wire.
1"
(2.5 cm)
3"
(7.6 cm)
2.Allow enough slack in the wire to easily attach the wiring terminal block.
3.Complete electrical connection according to your type of electrical supply
4-wire Connection: Direct Wire
Use this method for:
■New
■Mobile homes
■Recreational vehicles
■In an area where local codes prohibit grounding through the neutral
1.Part of metal ground strap must be cut out and removed.
A
B
C
A. Metal ground strap
B.Discard
C.
2.Use Phillips screwdriver to remove the
11