Electrical Connection - U.S.A. Only
Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death, fire, or electrical shock.
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death, fire, or electrical shock.
1. | Disconnect power. | Style 1: Power supply cord strain relief |
2. | Use Phillips screwdriver to remove the terminal block cover | ■ Assemble a UL listed strain relief in the opening. |
| screw located on the back of the range. Pull cover down and |
|
| toward you to remove cover. |
|
A
A. UL listed strain relief
3.Remove plastic tag holding three
■Feed the power supply cord through the strain relief in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
■Tighten strain relief screw against the power supply cord.
4.Add strain relief.