Whirlpool W10270322A installation instructions Bare Wire Torque Specifications, Wire Awg Torque

Page 12

3.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.

A

B

Bare Wire Torque Specifications

Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

Wire Awg

Torque

8 gauge copper

25 lbs-in. (2.8 N-m)

 

 

6 gauge aluminum

35 lbs-in. (4.0 N-m)

 

 

5.Use Phillips screwdriver to connect the bare (green) ground wire to the range with the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

6.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

 

C

G

D

 

F

E

 

A. Terminal block

E. Neutral (white) wire

B. Ground-link screw

F. Line 1 (black) wire

C. Cord/conduit plate

G. Bare (green) ground wire

D. Line 2 (red) wire

 

4.Attach terminal lugs to line 1 (black), neutral (white), and line

2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to

XX lbs-in. torque. See Bare Wire Torque Specifications chart.

A

B

C D E

G

A

B

 

 

F

 

D

E

C

 

 

 

A. 10–32 hex nut

 

E. Neutral (white) wire

B. Line 1 (black)

 

F. Line 2 (red)

C. Bare (green) ground wire

G. Terminal lug

D.Ground-link screw

7.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

8.Securely tighten hex nuts.

9.Replace terminal block access cover.

A. Terminal lug

B.Setscrew

C.Line 1 (black) wire

D.Neutral (white) wire

E.Line 2 (red) wire

12

Image 12
Contents Installation Instructions Freestanding Electric Range with Double OvensRange Safety Your safety and the safety of others are very importantInstallation Requirements Tools and PartsLocation Requirements Product Dimensions Cabinet Dimensions 35⁷⁄₈ 91.4 cm 29⁷⁄₈ 75.9 cm 26⁵⁄₁₆ 27¼ 66.8 69.2 cmIf connecting to a 4-wire system If connecting to a 3-wire systemElectrical Requirements Electrical ConnectionInstallation Instructions Adjust Leveling LegsUnpack Range Install Anti-Tip Bracket Floor MountingWall Mounting Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Electrical Connection U.S.A. OnlyStyle 2 Direct wire strain relief Removable retaining nut Strain reliefWire connection Power Supply Cord Direct Wire Installation Copper or Aluminum Wire Wire Connection Direct WireBare Wire Torque Specifications Wire Awg TorqueCord/conduit plate Line Black wire Verify Anti-Tip Bracket LocationComplete Installation Level RangeIf range does not operate, check the following For power supply cord-connected ranges For direct-wired rangesMoving the Range W10270322A