Whirlpool W10270322A installation instructions Product Dimensions Cabinet Dimensions

Page 4

Product Dimensions

 

Cabinet Dimensions

A

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

A freestanding range may be installed next to combustible walls with zero clearance.

E*

D

C

B

A

B

D

G

F

C

A. 46⁷⁄₈" (119.9 cm)

B. Model/serial number rating label (located on bottom right front of the toe kick plate)

C.35⁷⁄₈" (91.4 cm)

D.29⁷⁄₈" (75.9 cm)

E.26⁵⁄₁₆" - 27¼" (66.8 - 69.2 cm)*

E

*Excludes handle. Dimension given is from wall to front of oven door and will vary based on electric outlet receptacle installation.

A. 13" (33 cm) upper cabinet depth

B. 30" (76.2 cm) min. opening width

C. For minimum clearance to the top of the cooktop,

see NOTE.

D. 30" (76.2 cm) min. opening width

E. Cabinet door or hinge should not extend into cutout.

H

F.3-wire shaded area -

7" (17.8 cm) min. from left side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*

G. 4-wire shaded area -

10" (25.4 cm) min. from right side cabinet, 5¾" (14.6 cm) max. from floor, 6" (15.2 cm) max. width*

H. 1½" (3.8 cm) min. from floor if using a flush mount outlet.

*Nothing located in shaded areas can extend more than 1½" (3.8 cm) from wall or range will not slide all the way back.

NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.

4

Image 4
Contents Installation Instructions Freestanding Electric Range with Double OvensRange Safety Your safety and the safety of others are very importantTools and Parts Installation RequirementsLocation Requirements Product Dimensions Cabinet Dimensions 35⁷⁄₈ 91.4 cm 29⁷⁄₈ 75.9 cm 26⁵⁄₁₆ 27¼ 66.8 69.2 cmIf connecting to a 4-wire system If connecting to a 3-wire systemElectrical Requirements Electrical ConnectionAdjust Leveling Legs Installation InstructionsUnpack Range Floor Mounting Install Anti-Tip BracketWall Mounting Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Electrical Connection U.S.A. OnlyStyle 2 Direct wire strain relief Removable retaining nut Strain reliefWire connection Power Supply Cord Direct Wire Installation Copper or Aluminum Wire Wire Connection Direct WireBare Wire Torque Specifications Wire Awg TorqueCord/conduit plate Line Black wire Verify Anti-Tip Bracket LocationLevel Range Complete InstallationIf range does not operate, check the following For direct-wired ranges For power supply cord-connected rangesMoving the Range W10270322A