Broan RMIP45 Install Backsplash Optional, Custom Hood Preparation, RMIP33

Page 6

3. INSTALL BACKSPLASH (OPTIONAL)

It is recommended to install the backsplash before the custom hood insert. The custom hood will cover the backsplash top mounting screws. In order to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of custom hood and range control panel or cooktop. (See instructions packed with backsplash.)

4. CUSTOM HOOD PREPARATION

!WARNING

When building a custom hood, always follow all applicable construction codes and standards.

The custom hood frame must be sized to the shape and total weight of the insert assembly. Refer to the table below for total weight of the insert, according to the type of blower choosen.

INSERT MODEL

WITH P5 INT. BLOWER

WITH P8 INT. BLOWER

WITH IN-LINE OR EXT. BLOWERS (ROUGH-IN PLATE ONLY)

RMIP33

41 LB

49 LB

27 LB

RMIP45

49 LB

57 LB

35 LB

Start with the custom hood base, because its position will determine the height of the insert. We recommend the base of the custom hood should be 3/4 inch thick plywood. If an optional custom hood liner will be installed, we recommend the sides and front of the custom hood to be 3/4 inch thick, assuming standard cabinet widths. If the optional custom hood liner will not be installed, the custom hood side and front thickness is at the installer’s discretion.

Run power cable to installation location. Stub out a 4 foot length of electrical cable below the custom hood.

Backsplash

(Optional)

Plywood base thickness: 3/4”

4” for liner installation

24” to 30” above cooking surface

If the RMIPWC optional remote control will be installed, run electrical cable from the insert to the remote control location. Stub out a 6 inch length from the remote control wall location. Refer to the remote control installation instruction.

Standard 36” h. cooktop

HH0037A

5. SUGGESTED CUSTOM HOOD INTERNAL FRAMEWORK

The mounting holes for the 2 top stud supports are located at 119/16” up from the insert base. The on center distance between the 2 studs is 301/4” for the RMIP33 insert model and 421/4” for the RMIP45 insert model.

The mounting holes for the rear stud support are located at 11/2” up from the insert base. See illustration beside.

Once the custom hood base and frame are done, finalize the custom hood.

1 1/2”

HH0040A

- 6 -

Image 6
Contents Models RMIP33 and RMIP45 Flames do not GO OUT Immediately Evacuate and Call the Fire DepartmentRMIP33 and RMIP45 Insert System RmipwcIN-LINE and Exterior Blowers Select Blower Option and Install Ductwork Prepare the InstallationSuggested Custom Hood Internal Framework Install Backsplash OptionalCustom Hood Preparation RMIP33Install Blower Interior or Exterior Blower Install Custom Hood Liner OptionalInstall the Rmipwc Remote Control Optional CUT the Hole in Custom Hood BaseInstall the Deviator Interior Blower Install the Adapter Interior BlowerRemove the KNOCK-OUT Opening Interior Blower Connect Wiring ALL Blowers Install the ROUGH-IN Plate ALL BlowersInstall the Transition Interior Blower Install the Insert Install the Blower Interior BlowerDucting Connection ALL Blowers Install the Blower Interior Blower CONT’D Dual blower P8USE and Care Install FiltersLight Bulbs KIT no Insert Model RBFIP33 RMIP33 RBFIP45 RMIP45USE and Care CONT’D OperationWarranty 16 15 14 13 Dual BLOWER/ROUGH-IN