10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER)

Remove the knockout on rough-in plate. See picture below.

CAUTION

When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’ or 14’’ adapter/damper).

14’’

KNOCKOUT

10’’

KNOCKOUT

HD0077

Removing vertical knockout opening on rough-in plate

11. INSTALL THE DEVIATOR (INTERIOR BLOWER)

Install the deviator as shown.

NOTE: To prevent the deviator from sliding out of the rough-in plate, put some tape on the deviator base after sliding it into the rough-in plate (provided with the P5 and P8 blower) opening. If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.

HD0087

12. INSTALL THE ADAPTER (INTERIOR BLOWER)

Using two (2) no. 6 x 1/2’’ screws provided with insert, secure the adapter to the top of the rough-in plate. Remove tape from damper flap. Seal the adapter to the rough-in plate by using duct tape.

HD0005

HD0006

- 8 -

Image 8
Contents Models RMIP33 and RMIP45 Flames do not GO OUT Immediately Evacuate and Call the Fire DepartmentRMIP33 and RMIP45 Insert System RmipwcIN-LINE and Exterior Blowers Select Blower Option and Install Ductwork Prepare the InstallationInstall Backsplash Optional Custom Hood PreparationSuggested Custom Hood Internal Framework RMIP33Install Custom Hood Liner Optional Install the Rmipwc Remote Control OptionalInstall Blower Interior or Exterior Blower CUT the Hole in Custom Hood BaseRemove the KNOCK-OUT Opening Interior Blower Install the Deviator Interior BlowerInstall the Adapter Interior Blower Install the Transition Interior Blower Connect Wiring ALL BlowersInstall the ROUGH-IN Plate ALL Blowers Ducting Connection ALL Blowers Install the InsertInstall the Blower Interior Blower Install the Blower Interior Blower CONT’D Dual blower P8Install Filters Light BulbsUSE and Care KIT no Insert Model RBFIP33 RMIP33 RBFIP45 RMIP45USE and Care CONT’D OperationWarranty 16 15 14 13 Dual BLOWER/ROUGH-IN