Broan RMIP33 Install Custom Hood Liner Optional, Install the Rmipwc Remote Control Optional

Page 7

6. INSTALL CUSTOM HOOD LINER (OPTIONAL)

The liners are specially designed to protect the exterior base of the custom hood. To order, refer to the table below to find the right liner model number for your insert and width of custom hood. To view specific model information, including depths for each liner models, visit www.broan.com or contact Technical Support (phone number listed on front cover). To install, see instruction packed with custom hood liner.

The liner must be installed before the insert.

NOTE: On some liners models, front liner piece may overlap front insert flange. If so, remove the front liner piece, assemble insert, and reassemble front liner piece.

 

LINER MODEL

INSERT MODEL

CUSTOM HOOD

 

 

 

NOMINAL WIDTH

 

 

RML3336S

RMIP33

36’’

 

 

RML3342S

RMIP33

42’’

 

 

RML4548S

RMIP45

48’’

 

 

RML4554S

RMIP45

54’’

 

 

RML4560S

RMIP45

60’’

 

 

 

 

 

HA0038A

7. INSTALL THE RMIPWC REMOTE CONTROL (OPTIONAL)

The electrical connection for the remote control is located in front of the insert. Perform this connection before the insert installation. For installation details, see installation instructions included with the RMIPWC remote control.

HL0044

8. CUT THE HOLE IN CUSTOM HOOD BASE

If it is not done yet, cut a hole in the bottom of the cabinet, using the dimensions shown beside.

INSERT MODEL NUMBER

A

 

RMIP33

321/2’’

 

 

RMIP45

441/2’’

NOTES: 1. The notch shown in the inset must be cut only if the RMIPWC optional remote control will be installed.

2.The recommended distance from the back to the rearmost cutout edge is 21/4’’ minimum.

 

3 1/2''

17 1/16''

16 3/8''

2 1/4''

A

min.

 

HD0084

 

9. INSTALL BLOWER (INTERIOR OR EXTERIOR BLOWER)

INTERIOR BLOWER:

Follow all subsequent steps of this manual.

EXTERIOR BLOWER:

Refer to instructions packed with exterior blower and follow steps 13, 14, 16, 17, 19 and

 

up of this manual.

- 7 -

Image 7
Contents Models RMIP33 and RMIP45 Evacuate and Call the Fire Department Flames do not GO OUT ImmediatelyRmipwc RMIP33 and RMIP45 Insert SystemIN-LINE and Exterior Blowers Prepare the Installation Select Blower Option and Install DuctworkRMIP33 Install Backsplash OptionalCustom Hood Preparation Suggested Custom Hood Internal FrameworkCUT the Hole in Custom Hood Base Install Custom Hood Liner OptionalInstall the Rmipwc Remote Control Optional Install Blower Interior or Exterior BlowerInstall the Adapter Interior Blower Install the Deviator Interior BlowerRemove the KNOCK-OUT Opening Interior Blower Install the ROUGH-IN Plate ALL Blowers Connect Wiring ALL BlowersInstall the Transition Interior Blower Install the Blower Interior Blower Install the InsertDucting Connection ALL Blowers Dual blower P8 Install the Blower Interior Blower CONT’DKIT no Insert Model RBFIP33 RMIP33 RBFIP45 RMIP45 Install FiltersLight Bulbs USE and CareOperation USE and Care CONT’DWarranty 16 15 14 13 Dual BLOWER/ROUGH-IN