Broan RMIP33, RMIP45 Connect Wiring ALL Blowers, Install the ROUGH-IN Plate ALL Blowers

Page 9

13. CONNECT WIRING (ALL BLOWERS)

!WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

Position insert below the installed custom hood. Pull cable through hole in top of insert.

INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove rough-in plate wiring cover. Place the wire clamp in the knock-out hole, insert the cable through the wire clamp in the rough-in plate wiring box. Tighten the wire clamp to secure the cable.

Connect cable into wiring box using provided wire connectors.

Connect wires as follow: BLACK to BLACK, WHITE to WHITE and

GREEN or BARE wire under ground screw. DO NOT FORGET TO

CONNECT THE GROUND. Reinstall wiring cover.

HD0007

1

1) Ground screw

IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or exterior blower).

14. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)

INTERIOR BLOWER: Carefully install the rough-in plate inside the top of the insert with four

(4) lock nuts. See picture beside.

HD0042

IN-LINE OR EXTERIOR BLOWER: Refer to instructions included with rough-in kit. Secure the rough-in plate inside the top of the insert with (4) lock nuts.

15. INSTALL THE TRANSITION (INTERIOR BLOWER)

Slide the transition over the adapter/damper. Seal the transition to the adapter/damper by using duct tape.

HD0091

- 9 -

Image 9
Contents Models RMIP33 and RMIP45 Evacuate and Call the Fire Department Flames do not GO OUT ImmediatelyRmipwc RMIP33 and RMIP45 Insert SystemIN-LINE and Exterior Blowers Prepare the Installation Select Blower Option and Install DuctworkCustom Hood Preparation Install Backsplash OptionalSuggested Custom Hood Internal Framework RMIP33Install the Rmipwc Remote Control Optional Install Custom Hood Liner OptionalInstall Blower Interior or Exterior Blower CUT the Hole in Custom Hood BaseInstall the Deviator Interior Blower Install the Adapter Interior BlowerRemove the KNOCK-OUT Opening Interior Blower Connect Wiring ALL Blowers Install the ROUGH-IN Plate ALL BlowersInstall the Transition Interior Blower Install the Insert Install the Blower Interior BlowerDucting Connection ALL Blowers Dual blower P8 Install the Blower Interior Blower CONT’DLight Bulbs Install FiltersUSE and Care KIT no Insert Model RBFIP33 RMIP33 RBFIP45 RMIP45Operation USE and Care CONT’DWarranty 16 15 14 13 Dual BLOWER/ROUGH-IN
Related manuals
Manual 48 pages 62.6 Kb Manual 48 pages 30.63 Kb