CONNECT THE DUCTWORK
Duct tape all connecton’s to make them secure and air tight.
DUCTED HOODS ONLY
1.Connect 6” diameter metal duct to ducting that discharges to the outside.
NON-DUCTED HOODS ONLY
2.Connect 5” diameter expandable metal duct from the
DUCTED AND NON-DUCTED HOODS
3.Remove the tape from the lower flue. Lower the flue until is seats on top of the hood.
4.Remove duct tape from upper and lower flue. Lower the flue until it seats on top of the hood.
6” DUCTED
CONNECTION
TAPE
5”
CONNECTIONFIG.19
INSTALL ELECTRICAL
WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.
1.Remove the wiring box cover. Fig. 20.
2.Run
3.Secure cable to box with an appropriate cable connector.
4.Feed the range hood’s power cable through the hole in the bottom of the wiring box.
5.Secure the cable to the box using the wire clamp (supplied in the parts bag).
6.Connect wires,
7.Push wiring into the electrical box. Reinstall the wiring box cover.
8.Raise the upper flue and reinstall mounting screws.
LINE IN 120 VOLTS - 60 HZ
WIRING BOX
COVER
WIRE CLAMP
| |
FIG.20 |
- 13 -