PREPARE SUPPORT FRAME
8 AND 9-FOOT CEILINGS
1.Measure the ceiling height and determine distance between the cook top and bottom of hood.
2.Remove (4) screws and washers in the height adjustment slots. Figure 8.
3.Per the chart, adjust overall lenght of the support frame. Figure 8.
4.Reinstall (4) screws and washers in the height adjustment slots. Figure 8.
HEIGHT
ADJUSTMENT
SLOTS
FRONT
FIG. 8
CEILING |
|
| HOOD DISTANCE ABOVE 36” HIGH COOK TOP (See note a) |
| ||||||
DUCT METHOD | 24” |
| 25” | 26” | 27” | 28” | 29” |
| 30” | |
HEIGHT |
|
|
| LENGHT OF SUPPORT FRAME, DIMENSION “A” |
| |||||
|
|
|
|
| ||||||
8 FOOT | DUCTED | 22” |
| 21” | 20” |
|
|
|
|
|
CEILING | NON DUCTED | 22” |
| 21” | 20” | 19” | 18” |
|
|
|
9 FOOT | DUCTED & |
|
|
| 32” | 31” | 30” | 29” |
| 28” |
CEILING | NON DUCTED |
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||
10 FOOT | DUCTED & | 46” |
| 45” | 44” | 43” | 42” | 41” |
| 40” |
CEILING | NON DUCTED |
|
| |||||||
|
|
|
|
|
|
|
|
| ||
(see note |
|
|
|
|
|
|
|
|
|
|
b) |
|
|
|
|
|
|
|
|
|
|
Notes:
a.Minimum hood distance above cook top must not be less than 24”.
A maximun of 30” above cook top is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer’s and user’s discretion; providing that ceiling height and flue length permit.
b.Requires optional
10-FOOT CEILINGS
Note: The following materials must be purchased separately for
•
•
Flue extension model FX54SS for ducted installations
Flue extension model FXN54SS for
5.Discard the upper support frame half supplied with the range hood. Replace with the longer upper support frame supplied with the flue extension.
6.Follow steps 1 through 4 shown above.
- 9 -