Broan Comprehensive Guide to Using Your E54000 Ventilation Hood

Page 4

OPERATION

 

 

 

 

LIGHT

BLOWER

 

 

Controls

 

SWITCH

 

SWITCH

The hood is operated using the slide controls

 

 

 

 

PILOT

under the bottom of the hood.

 

 

LAMP

The light switch turns the lamps on and off.

 

 

 

The blower switch turn the blower on to three speed settings:

0

- OFF

 

 

 

1

- LOW SPEED

 

 

 

2

- MEDIUM SPEED

 

 

 

FIG. 1

 

3

- HIGH SPEED

 

 

 

The pilot lamp lights up whenever the blower is on.

HEAT SENTRY™

Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1)If blower is OFF - it turns blower ON to HIGH speed.

2)If blower is ON at a lower speed setting - it turns blower up to HIGH speed. When the temperature level drops to normal, the blower will return to its original setting.

WARNING: The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.

HALOGEN BULBS

This range hood requires (4) halogen bulbs (Type T3, 12Volt, 20 Watt Max, G-4 Base).

WARNING: Always switch off the electricity supply before carrying out any operations on the appliance.

To change bulbs:

1.Loosen the ring nut by turning it counterclockwise.

2.Remove the bulb by pulling sideward(DO

NOT ROTATE).

CAUTION: Bulb may be hot!

3.Replace with Type T3, 12Volt, 20 Watt Max, G-4 Base halogen bulb. Do not touch replacement bulb with bare hands!

Do not use bulbs greater then 20 Watts. Bulbs greater than 20 Watts will cause fuse to open.

- 4 -

RING NUT

FIG. 2

Image 4
Contents Model E54000 Read and Save These Instructions Intended for Domestic Cooking only WarningPage Operation Halogen BulbsControls Heat SentryFuse Replacement Maintenance Hood CleaningGrease Filter Non-ducted Recirculation FilterPrepare the Hood Install Support System Install the DuctworkDucted Hoods only 9-FOOT Ceilings Prepare Support FrameFoot Ceilings Prepare Support FRAME, cont’dDucted and NON-DUCTED Hoods NON-DUCTED Hoods onlyPrepare the HOOD, cont’d Install Upper Decorative FlueDucted Hoods only 8-FOOT and 9-FOOT Ceilings Install the Upper Decorative FLUE, cont’d Install Lower Decorative FlueInstall the Hood NON-DUCTED Hoods only 8-FOOT and 9-FOOT CeilingsInstall Electrical Connect the DuctworkInstall Filters WarrantyPour Utilisation Domestique Seulement Avertissement AvertissementPage Commandes FonctionnementAmpoules Halogènes Heat SentrymcRemplacement DU Fusible Entretien Filtres à graissesFiltre à charbon Nettoyage de votre hottePréparation DE LA Hotte Installation DU Système DE Support Installation DU Système DE ConduitsHottes À Évacuation Extérieure Seulement Préparation DE LA Structure DE Support Plafonds DE 10 PIPréparation DE LA Structure DE Support suite Hottes À Évacuation ET À RecirculationHottes À Évacuation Seulement Hottes À Recirculation SeulementPréparation DE LA Hotte suite Hottes À Évacuation Seulement Plafonds DE 8 PI ET DE 9 PIInstallation DE LA Hotte Montage DU ConduitDécoratif Supérieur suite Montage DU Conduit Décoratif InférieurInstallation Électrique Raccord DES ConduitsGarantie Installation DES FiltresHottes Àrecirculationseulement LEA Y Conserve Estas Instrucciones AdvertenciaAdvertencia Lamparas Halogenas FuncionamientoMandos Sustitución DEL Fusible Filtro al carbón configuración sin tubo MantenimientoFiltro antigrasa Limpieza de la campanaPrepare LA Campana Chimenea Armazón DE Decorativa Soporte Arandelas DentadasInstalacion DEL Tubo DE Extraccion Instalacion DEL Sistema DE SujecionPreparación DEL Armazón DE Soporte Techos DE 10 PiesPreparación DEL Armazón DE SOPORTE, Preparación DE LA CampanaCampanas CON O SIN Conducto Sólo Para Campanas CON ConductoMontaje DE LA Chimenea Decorativa Superior Preparación DE LA CAMPANA,Sólo Para Campanas CON Conducto Techos DE 8 O 9 Pies Montaje DE LA Chimenea Decorativa SUPERIOR, Montaje DE LA Chimenea Decorativa InferiorInstalación DE LA Campana Sólo Para Campanas SIN Conducto Techos DE 8 O 9 PiesConexión DE LA Tubería Instalación EléctricaConfiguración CON Conducto Y SIN Conducto Configuración SIN ConductoInstalación DE Filtros GarantiaService Parts Model E54000Liste DES Pièces DE Rechange Modèle E54000Lista DE Piezas DE Recambio Modelo E5400004307632/1N