Broan 355BR, 356BK, 350 warranty Read and Save These Instructions, Tools and Materials Required

Page 1

MODELS 350 • 350BK • 350BR • 355 • 355BK • 355BR 356 • 356BK • 356BR • 358

ROOF-MOUNT

POWERED ATTIC VENTILATOR

Page 1

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCETHE RISK OF FIRE,ELECTRIC SHOCK,OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting.Follow the heating equipment manufac- turer's guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Condition- ing Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.The wiring must be permanent. DO NOT USE AN EXTENSION CORD! Use 14 GA.MINIMUM copper wire.Although the Powered Attic Ventilator may be wired directly to power, we advise that some type of shut off switch be installed in the line. Please see the section on electrical wiring for suggested wiring diagrams and instructions.

7.This unit must be grounded.

8.Do not use this unit with any solid state speed control device (Models 356 and 358 only).

TOOLS AND MATERIALS REQUIRED

CAUTION

1.For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.

4.Fan is equipped with a thermostat which may start fan automati- cally.To reduce risk of injury or electric shock while servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5.Home Ventilating Institute (HVI) recommends one square foot of open air inlet per 300 cfm of fan capacity. The best location for these air intake vents are under the eaves with direct ac- cess to the attic. Failure to provide these intakes could cause natural-draft gas appliances to backdraft.

6.Your attic fan installation will create a screened opening into your attic space. During a heavy rain storm there could be a light spray of rain into this attic space. This is a normal condi- tion with all attic ventilators and will not cause any damage to the structure. We recommend that you do not store any valu- able articles directly under the fan opening in the roof. During extreme rain and wind storms you may want to turn on your attic ventilator to prevent excess moisture accumulation in your attic.

7.Records show, under ideal conditions, exposed galvanized steel can remain rust free up to 100 years. For best protection, the exposed portion of the roof sheet should be painted, especially in areas of unusually high industrial air pollution. Follow paint manufacturer's instructions for good adhesion.

8.This ventilator is intended for roof installation.The Broan Model 353 Gable MountVentilator is available for side wall applications.

9.The dome may be painted with a high-quality paint. Follow the paint manufacturer's recommendations for PVC plastic or aluminum, as appropriate.

10.Please read specification label on product for further information and requirements.

rSlotted Screwdriver

rDrill

r1/4" Drill Bit

rSabre Saw or Keyhole Saw

rHammer

rRuler

rPencil

rUtility Knife

rPry Bar (to remover roofing nails)

rRoofing Cement

rGalvanized Roofing Nails (1¾" min.)

rElectrical Supplies (to comply with codes)

Image 1
Contents Tools and Materials Required Read and Save These InstructionsModels 350 350BK 350BR 355 355BK 355BR 356 356BK 356BR Models 350 350BK 350BR 355 355BK 355BR 356 356BK 356BR Models 350 350BK 350BR 355 355BK 355BR 356 356BK 356BR FAN on KEY Service PartsService Parts BROAN-NUTONE ONE Year Limited Warranty Warranty

356BR, 355BK, 350BK, 358, 356 specifications

The Broan 358, 350, 355BK, 350BK, and 355BR are part of Broan's esteemed lineup of range hoods, designed to enhance kitchen ventilation while seamlessly integrating with various kitchen decors. Each model showcases a blend of performance, efficiency, and style, making them indispensable for cooking enthusiasts.

The Broan 358 is a ducted range hood that stands out for its powerful 250 CFM blower, ensuring effective removal of smoke, steam, and odors. Equipped with a two-speed fan control, users can easily adjust the ventilation level to match cooking needs. The lightweight design and easy-to-install features allow for quick upgrades to existing kitchen spaces.

Model 350 is another superb offering with a classic design that fits various kitchen styles. This range hood features a streamlined body crafted from durable stainless steel, providing both longevity and style. Its 230 CFM motor works efficiently to clear airborne contaminants while operating quietly, contributing to a pleasant cooking environment. Additionally, this model includes a protective duct cover that allows for easy installation and a polished look.

The Broan 355BK and 350BK are standout black models that bring sophistication and elegance to the kitchen. Both feature a 400 CFM blower option for enhanced performance, addressing heavy cooking demands with ease. Equipped with two lights, these hoods not only illuminate the cooking area but also add a touch of design flair. Their control switches are conveniently located, offering effortless operation during meal preparation.

Lastly, the 355BR model presents an appealing bronze finish, making it a striking centerpiece in any kitchen. This model also features a 400 CFM blower, ensuring excellent ventilation. The convertible design allows users to install it as either ducted or ductless, providing flexibility depending on kitchen layouts and user preferences.

All these models include dishwasher-safe aluminum filters, guaranteeing simple maintenance and hygiene. The improved airflow and stylish exteriors combined with cutting-edge technologies like variable speed controls and easy installation options make the Broan range hoods an ideal choice for modern kitchens. Whether you prioritize performance or aesthetics, Broan’s 358, 350, 355BK, 350BK, and 355BR models deliver it all, enhancing the cooking experience while ensuring your kitchen remains fresh and inviting.