J. T. Eaton LCX9000 user manual Appendix A - Fault Codes, Table A-1 Fault Codes

Models: LCX9000

1 128
Download 128 pages 41.65 Kb
Page 111
Image 111
Appendix A — Fault Codes

LCX9000 Liquid-Cooled Drives User Manual

January 2007

Appendix A — Fault Codes

When a fault is detected by the drive’s control electronics, the drive is stopped and the symbol F together with the ordinal number of the fault, the fault code and a short fault description appear on the display. The fault can be reset with the RESET button on the control keypad or via the I/O terminal. The faults are stored in the Fault History Menu M5, which can be browsed. Table A-1contains all the fault codes.

Table A-1: Fault Codes

Fault

 

 

 

Code

Fault

Possible Cause

Solution

 

 

 

 

 

 

 

 

1

Overcurrent

Drive has detected too high a current

Check loading.

 

 

in the motor cable:

Check motor.

 

 

• sudden heavy load increase

Check cables.

 

 

• short circuit in the motor cables

 

 

 

• unsuitable motor

 

2

Overvoltage

The DC-link voltage has exceeded

Set the deceleration time longer.

 

 

the limits defined in Table 1-4:

Add a brake chopper or brake

 

 

• too short a deceleration time

resistor.

 

 

• high overvoltage spikes in supply

 

3

Ground Fault

Current measurement has detected

Check motor cables and motor.

 

 

that the sum of motor phase currents

 

 

 

is not zero.

 

 

 

• insulation failure in cables or

 

 

 

motor

 

 

 

 

 

5

Charging Switch

The charging switch is open, when

Reset the fault and restart.

 

 

the START command has been

Should the fault re-occur, contact

 

 

given.

your Cutler-Hammer distributor.

 

 

• faulty operation

 

 

 

• component failure

 

6

Emergency stop

Stop signal has been given from the

 

 

 

option board.

 

 

 

 

 

7

Saturation trip

Various causes:

Cannot be reset from the keypad.

 

 

• component failure

Switch off power.

 

 

• brake resistor short circuit or

DO NOT RE-CONNECT POWER!

 

 

overload

Contact Eaton.

 

 

 

If this fault appears simultaneously

 

 

 

with Fault 1, check motor cables and

 

 

 

motor.

 

 

 

 

8

System fault

• component failure

Reset the fault and restart.

 

 

• faulty operation

Should the fault reoccur, contact

 

 

Note: exceptional fault data record,

your Cutler-Hammer distributor.

 

 

see Page 5-12.

 

 

 

 

 

Programmable.

 

 

MN04005001E

For more information visit: www.EatonElectrical.com

A-1

Page 111
Image 111
J. T. Eaton LCX9000 user manual Appendix A - Fault Codes, Table A-1 Fault Codes