J. T. Eaton user manual 6 Fuse Sizes for LCX9000 Liquid-Cooled 690V Drives, Fuse information

Models: LCX9000

1 128
Download 128 pages 41.65 Kb
Page 52
Image 52
Table 3-6: Fuse Sizes for LCX9000 Liquid-Cooled (690V) Drives

LCX9000 Liquid-Cooled Drives User Manual

 

 

 

 

 

 

 

 

 

 

 

January 2007

 

Table 3-6: Fuse Sizes for LCX9000 Liquid-Cooled (690V) Drives

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN43620

 

DIN43653 (80 mm)

DIN43653 (110 mm)

 

 

Qty. of

 

 

 

 

 

 

 

 

 

Fuse

Fuse

Fuses per

 

 

 

 

 

 

 

 

 

Chassis

Catalog

Ith

aR Fuse

Fuse

aR Fuse

Fuse

aR Fuse

Fuse

Un

In

Phase

Number

(A)

Part No.

Size

Part No.

Size

Part No.

Size

(V)

(A)

3~

 

 

 

 

 

 

 

 

 

 

 

 

CH61

LCX170A0-5

170

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX208A0-5

208

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX261A0-5

261

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

1

 

 

 

 

 

 

 

 

 

 

 

 

CH72

LCX325A0-5

325

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX325A0-5

325

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX385A0-5

385

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX385A0-5

385

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX416A0-5

416

170M6812

DIN3

170M6062

3TN/80

170M6212

3TN/110

690

800

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX416A0-5

416

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX460A0-5

460

170M6812

DIN3

170M6062

3TN/80

170M6212

3TN/110

690

800

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX460A0-5

460

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX502A0-5

502

170M6812

DIN3

170M6062

3TN/80

170M6212

3TN/110

690

800

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX502A0-5

502

170M3819

DIN1

170M3069

1xTN/80

170M3219

1xTN/110

690

400

2

 

 

 

 

 

 

 

 

 

 

 

 

CH63

LCX590A0-5

590

170M6814

DIN3

170M6064

3TN/80

170M6214

3TN/110

690

1100

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX650A0-5

650

170M8547

3SHT

170M6066

3TN/80

170M6216

3TN/110

690

1250

1

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX750A0-5

750

170M8547

3SHT

170M6066

3TN/80

170M6216

3TN/110

690

1250

1

 

 

 

 

 

 

 

 

 

 

 

 

CH74

LCX820A0-5

820

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX820A0-5

820

170M6812

DIN3

170M6062

3TN/80

170M6212

3TN/110

690

800

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX920A0-5

920

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCX920A0-5

920

170M6812

DIN3

170M6062

3TN/80

170M6212

3TN/110

690

800

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH10A0-5

1030

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH10A0-5

1030

170M6814

DIN3

170M6064

3TN/80

170M6214

3TN/110

690

1000

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH11A0-5

1180

170M5813

DIN2

170M5063

2TN/80

170M5213

2TN/110

690

700

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH11A0-5

1180

170M6814

DIN3

170M6064

3TN/80

170M6214

3TN/110

690

1000

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH13A0-5

1300

170M6814

DIN3

170M6064

3TN/80

170M6214

3TN/110

690

1000

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH13A0-5

1300

170M8547

3SHT

170M6066

3TN/80

170M6216

3TN/110

690

1250

2

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH15A0-5

1500

170M6814

DIN3

170M6064

3TN/80

170M6214

3TN/110

690

1000

3

 

 

 

 

 

 

 

 

 

 

 

 

 

LCXH15A0-5

1500

170M8547

3SHT

170M6066

3TN/80

170M6216

3TN/110

690

1250

2

 

 

 

 

 

 

 

 

 

 

 

 

Tj = 77°F (25°C).

SHT fuses can be assembled into DIN fuse base of the corresponding size.

Note: Data in italic refer to drives with 12-pulse supply.

Fuse information

Max fuse ambient temperature +122°F (+50ºC).

Fuse sizes can differ in the same chassis. Fuses can be chosen according to the highest current rating of the chassis to minimize fuse variants.

Check the current rating of the fuse bases according to the input current of the drive.

The physical size of the fuse is chosen on the basis of the fuse current: Current <400 amps (size 2 fuse or smaller), current <400 amps (size 3 fuse).

3-6

For more information visit: www.EatonElectrical.com

MN04005001E

Page 52
Image 52
J. T. Eaton user manual 6 Fuse Sizes for LCX9000 Liquid-Cooled 690V Drives, Fuse information