Status LEDs (Green – Green – Red)

LCX9000 Liquid-Cooled Drives User Manual

January 2007

Status LEDs (Green – Green – Red)

The status LEDs light up in connection with the READY, RUN and FAULT drive status indicators.

Table 5-3: Status LEDs (Green – Green – Red)

Indicator

Description

Lights up with the AC power connected to the drive. Simultaneously, the drive status indicator READY is lit up.

Lights up when the drive is running. Blinks when the STOP button has been pushed and the drive is ramping down.

Lights up when unsafe operating conditions were encountered due to which the drive was stopped (Fault Trip). Simultaneously, the drive status indicator FAULT blinks on the display and the fault description can be seen, see Page 5-11, Active faults.

Text Lines

The three text lines provide the users with information on their present location in the keypad menu structure as well as with information related to the operation of the drive.

Table 5-4: Text Lines

Indicator

Description

Location indicator: displays the symbol and number of the menu, parameter,

etc. Example: M2 = Menu 2 (Parameters); P2.1.3 = Acceleration time.

Description line: Displays the description of the menu, value or fault.

Value line: Displays the numerical and textual values of references, parameters, etc. and the number of submenus available in each menu.

Keypad Pushbuttons

The alphanumeric control keypad has nine pushbuttons that are used for controlling the drive (and motor), setting parameters and monitoring values.

Figure 5-2: Keypad Pushbuttons