Connection
Carry out the connection to the gas plant only by means of a rigid metallic pipe conforming to the regulations in force.
The joint for the entry of gas into the appliance is threaded GJ 1/2".
Carry out the connection avoiding any type of stress on the appliance.
Natual gas appliances must be fitted with a pressure regulator and be installed at the inlet connection. The gas pressure must then be set as a part of the commissioning procedures.
For
Important
Upon completion of installation, always check:
λthat all the joints are completely sealed by using a soapy solution, never a flame;
λthat the gas pressure has been regulated to 1.00kPa for Natural Gas and 2.75kPa for
λthat the automatic ignition system is operating satisfactory on all burners, both individually and in combination;
λthat the burners operate correctly, are stable, without yellow tipping or excessive noise on high and low flame.
Then demonstrate to the customer the appiance operation and leave these instructions.