Electrical connections
The appliance is predisposed to function with a
Before connecting ensure that:
- The limiter valve and the electrical mains |
can support the voltage of the appliance |
(see registration plate). |
Fig.10 | FO 0480 |
Neutral wire
Phase
- | The power supply is correctly earthed |
| according to the regulations in force. |
- | The plug or omnipolar interrupter used |
| can be easily reached once the |
| appliance has been installed. |
The appliance is supplied with a supply cord incorporating a plug. Connect the plug to an appropriate security socket.
If a direct connection to the mains is required, an omnipolar interrupter with a minimum opening of 3mm between contacts, dimensioned to the voltage and corresponding to the regulations in force, should be interposed between the appliance and the supply. The yellow/green earth cable must not be interrupted by the interrupter. The brown coloured phase cable (situated at terminal “L” of the terminal box) must always be connected to the network phase. The voltage cable must always be positioned in such a manner that it at no point reaches a temperature of
50 °C above room temperature. An example of the best routing is shown in fig. 11.
In case of substitution of the voltage cable use cable type H05 RRF having a section suited to the charge, it is furthermore necessary that the yellow/green earth wire be approximately 2cm longer than the phase and neutral wires (Fig. 10).
Fig.11
Ground (yellow - green)
YES
Gas pipeline
Electric wire
Gas pipeline
Electric wire
Gas pipeline
Electric wire
NO
After connection try out the heating elements allowing them to function for approximately 3 minutes.
The manufacturer declines all responsibility in case the prevention of accidents regulations are not respected.
26