Best IP29M Series installation instructions Operation, Cooktop Lighting Halogen

Page 13

21.OPERATION

Always turn ON your hood before you begin cooking in order to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.

1

2

5

6

7

8

9

10

11

3

4

max

ENSO

 

S

R

HC0032

1.Halogen light push-button

INSTEON™ Master Link Mode push-button

2.Blower push-button

3.Enable/Disable functions push-button/ INSTEON™ Erase Link push-button

4.Grease filter reset push-button/ INSTEON™ Link Mode push-button

5 Grease filters maintenance icon

AIR

REFRESH

6.Maximum blower speed icon

7.Particulates sensor icon

8.Blower speed level/ INSTEON™ state icon

9.Air refresh function icon

10.Blower speed icon

11.INSTEON™ icon

Cooktop Lighting (Halogen)

The halogen lighting is controlled by the light push-button (item 1 on illustration above). Push once to turn ON the lights, and push a second time to turn the lights ON to a brighter level. If the lights are at the highest level, pressing another time will set them to the lowest intensity.

Press on the push-button and maintain for 1 second to turn Off the lights and set the memorized intensity. When turned on, the halogen bulbs will light cooktop at the previous setting.

Use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (included).

Blower

The blower is controlled by the blower push-button (item 2 on illustration above). Push once to turn ON the blower, and push a second time to set the blower speed to a higher level. If the blower speed is on maximum level, pressing another time will turn the blower to the lowest speed.

When power level 1 is activated from OFF, 100% of power level is activated during 0.3 second acting as a “kick-start”.

Press on the push-button and maintain for 1 second to turn Off the blower and set the memorized speed. When turned ON, the blower will operate at the previous setting.

When the blower is ON, the speed level is shown by the center icon (item 8 on illustration above) while the icon 10 appears (the speed of the rotational movement is proportional to the blower speed).

When the blower is on the higher speed, the icon 10 shuts off and the icon 6 appears with “max” (the symbol has a rotational movement).

Functions

Pressing on Enable/Disable functions push-button (item 3 on illustration above) allows to control Particulate Sensor and Air Refresh hood functions.

Particulates Sensor

To activate the particulate sensor function, press on Enable/Disable functions push-button (item 3 on illustration above), the particulates sensor icon (item 7 on illustration above) will appear.

When the sensor is activated, the blower turns ON automatically when some particulates, vapors or smokes caused by cooking process, or abnormal gas emissions in the environment are detected. The blower speed is automatically set depending on the particulates amount and the sensibility settings of the particulates sensor. See next paragraph.

To stop the particulates sensor function, press on Enable/Disable functions push-button until particulates sensor icon turns off.

Particulates sensor sensibility settings

Press on Enable/Disable functions push-button (item 3 on illustration above) to activate the particulate sensor function, this will light up the particulates sensor icon (item 7 on illustration above). Then, press and maintain for 2 seconds the Enable/Disable functions push-button : the sensor sensivity level will appear on center icon (item 8 on illustration above).

Press again on this push-button to change the sensor sentivity level (from 0 [minimum sensitivity] up to 9 [maximum sensitivity]).

Press on the grease filter reset push button (item 4 on the illustration above) to confirm (or is confirmed automatically after 5 seconds).

Air Refresh

To activate the air refresh function, press on Enable/Disable functions push-button (item 3 on illustration above), the air refresh function icon (item 9 on illustration above) will appear.

To stop the air refresh function, press on Enable/Disable functions push-button until air refresh icon turns off.

Air refresh function activates only when blower is OFF. When activated, the blower hood recycles the air in the environment in perfect silence, starting every 50 minutes (for 10 minutes, on first speed).

- 13 -

Image 13
Contents IP29M Series Never Pick UP a Flaming PAN-You may be burned To Reduce the Risk of a Range TOP Grease FireBLOWER/ROUGH-IN KIT IP29M Series Range Hood System Interior BlowersIP29M Series Range Hood System IN-LINE and Exterior Blowers Model P6 Single Interior Blower Typical Ductwork Select Blower Option and Installation TypePrepare the Installation Measure InstallationRemove the Filters and the Grease Drip Rail Prepare the Blower HousingRemove the PAN Build the Framework Secure Blower Housing to Brackets Install Blower HousingInstall Transition to ROUGH-IN Plate Interior Blower only Install the ROUGH-IN Plate in the Blower HousingInstall the Hood Connect the WiringReinstall Grease Drip Rail and Baffle Filters Reinstall the PANLight Bulbs Replacement Cooktop Lighting Halogen OperationOperation CONT’D Grease filter resetIP29M Series Service PartsONE-YEAR Limited Warranty Warranty