2. MEASURE INSTALLATION
Dimensions for the most common installation are shown beside.
The minimum hood distance above cooktop must not be less than 30’’. A maximum of 36” above cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” are at the installer and users discretion.
Since framework must be flush to ceiling, 4 decorative flue covers have been created to fit both hood widths and different ceiling heights. Refer to table below to choose the model that fits your needs.
DECORATIVE FLUE COVER | 8’ CEILING |
| 9’ CEILING | |||||
DISTANCE FROM COOKTOP | DISTANCE FROM COOKTOP | |||||||
|
|
| ||||||
MODEL | A (HEIGHT) | WIDTH | 30” | 36” | 30” |
| 36” | |
AEIP422 | 12” | 42” |
| X |
|
|
| |
AEIP542 | 12” | 54” |
| X |
|
|
| |
AEIP428 | 18” | 42” | X |
|
|
|
| |
AEIP548 | 18” | 54” | X |
|
|
|
| |
AEIP424 | 24” | 42” |
|
|
|
| X | |
AEIP544 | 24” | 54” |
|
|
|
| X | |
AEIP420 | 30” | 42” |
|
| X |
|
| |
AEIP540 | 30” | 54” |
|
| X |
|
| |
|
|
|
|
|
|
|
|
NOTE: For ceilings over 9’, decorative flues are not available.
Framework flush to ceiling
Decorative flue | A | |
cover or drywall | ||
| ||
with trim |
|
Minimum distance between the hood and cooktop:
30’’ (762 mm)
Recommended maximum distance between the hood and cooktop: 36’’ (914 mm)
| Standard 36” |
| (914 mm) |
HH0084A | high cooktop |
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
If a drywall box will be built instead of installing decorative flue cover, use drywall trim to hide hood and drywall junction. Refer to table below to find the appropriate model for your hood width.
MODEL | WIDTH |
ATDIP42 | 42” |
ATDIP54 | 54” |
|
|
3. PREPARE THE INSTALLATION
CAUTION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
-Installation manual
-Accessories including:
•3 Evolutionary™ hybrid baffle filters
•Shielded halogen lights (GU10 type base, 120 V, 50 W) (6 for 42” width hoods, 8 for 54” width hoods)
•Bag of parts including:
(10)steel wood screws no. 10 x 1.5’’, (10) steel washer no. 10, (6) screws no. 8 x 3/8’’ (additional screws provided)
Parts sold separately:
-Interior blower Model P6 (includes
-Interior blower Model P12 (includes
-
-Exterior blower assembly EB6, EB9, EB12 or EB15 (all include
-Transitions, duct, elbows, dampers, wall and roof caps. Refer to pages 3 and 4 for a complete list of venting options and model numbers.
-Optional decorative flue cover AEIWP Series, 12’’, 18”, 24” or 30” height and 42” or 54” width.
-Optional dry wall trim ATDIP Series, 42” or 54” width.
- 6 -