Bakers Pride Oven LPF-FC service manual Electric Pressure Fryer Operation

Page 14

Electric Pressure Fryer

Operation

 

 

 

 

 

 

Item #

Description

Function

8

ALARM button

This button allows the user to set an elapsed time at which the

 

 

internal alarm will sound during a cycle. The time is set by

 

 

pressing and holding the ALARM button while using the UP and

 

 

DOWN arrows to change the time. The controller will limit the

 

 

alarm time to be less than the currently programmed interval cycle

 

 

time. The default alarm time is 0:00 which disables it. The ALARM

 

 

time is saved on power down in the same manner as the last

 

 

interval time. When a time cycle is running and the alarm time has

 

 

elapsed the internal alarm will sound for 10 seconds. For

 

 

example, a cycle time 10:00 and alarm time of 2:00 would cause

 

 

the alarm to sound for 10 seconds once the controller has counted

 

 

down from 10:00 to 8:00. This button is used to cancel the STIR

 

 

OIL alarm. This button is also used to reconfigure the STIR OIL

 

 

Function.

 

A, B, C, D preset

These buttons are used to save and recall preset cycle and alarm

 

buttons

times, saving operator time and minimizing error when changing

 

 

interval cycle times and alarm times. To save the current interval

 

 

and alarm times into one of the preset locations, press and hold

 

 

the A, B, C, or D preset button for 2 seconds and the controller will

 

 

double chirp to indicate the times have been saved. To recall any

 

 

preset time, press and quickly release the appropriate button and

 

 

the time values are loaded and displayed. These buttons are also

 

 

used to reconfigure the STIR OIL function.

 

Beeper

A beeper sounds when the timer counts down to 0. Pressing the

 

 

START/STOP button stops the beeper and resets the timer

 

 

causing the display to return to the original starting time. At this

 

 

point, time can be changed using the TIME SELECT buttons or

 

 

the preset buttons. The beeper will also sound for 10 seconds if

 

 

the alarm time has elapsed during a timing cycle. When the STIR

 

 

OIL function begins the beeper will sound until the ALARM or

 

 

START/STOP button is pressed.

 

Display

Used to display the time. It also displays the words “STIR” then

 

 

“OIL” in .5 second intervals until the ALARM or START/STOP

 

 

button is pressed.

9

High Limit Reset

Located under the control panel. If the heating elements inside the

 

Switch

pot reach an unsafe temperature, power is automatically removed

 

 

from the control panel and elements. Pressing this switch returns

 

 

power to the control panel and elements.

10

Drain Lever

DRAIN OPEN – When placed in this position, the drain valve

 

 

opens and shortening in the pot drains into the vat. Also power is

 

 

removed from the control panel and elements.

 

 

DRAIN CLOSED – When placed in this position, the drain valve is

 

 

closed to prevent shortening from draining from the pot.

11

Fill Lever

FILL THRU POT – When placed in this position, shortening can

 

 

be pumped automatically from the vat to the pot if the rocker

 

 

switch is in the FILTER position.

 

 

FILL THRU HOSE – When placed in this position, shortening can

 

 

be pumped from the vat to the pot via a connected hose if the

 

 

rocker switch is in the FILTER position.

12

Rinse Hose Connector

Used to connect the Rinse hose for cleaning and refilling the pot.

13

Pump Motor Reset

If the motor overheats while filtering, it will automatically shut off.

 

Switch

Wait 15 minutes to allow motor to cool before pressing this switch.

12

Image 14
Contents Electric Pressure Fryer Warranty Information Table of Contents Safety Precautions Safety Signs and MessagesFull Disconnection Specific PrecautionsEquipotential ground plane Noncombustible Floors Only Safe Work PracticesDo Not Overload The Basket With Food Never Loosen The Spin Handle Until Pressure Gauge Is At Zero Keep Safety Labels Clean and in Good Condition Safety Labels Installation Controls and Indicators OperationCanceling The Stir OIL Function Pressing this button cancels Item # Description FunctionElectric Pressure Fryer Operation Start-Up LPF and LPF-F Care of the ShorteningLPF and LPF-F Operation KEY Display Mode Description Cooking LPF and LPF-FElectric Pressure Fryer Operation LPF-FC Operation System ProgrammingStep Action Display Comments Product Programming Product Programming SequenceProgram Product # Step Action Display Comments ALF and BLF AutomaticStart-Up LPF-FC Cooking LPF-FCElectric Pressure Fryer Operation Recipes Pork Chops Whole Turkey 12 to 14 poundsWhole Duckling Cube Or Minute SteaksMaintenance Description Assembly # AssembliesItem # QTY Description Drain Valve Replacement Thread Insert 10-24 Steel Drain/Motor/Piping Assembly VALVE,DRAIN SS BALL&PLT.CAR.STEM Control Panel LPF/LPF-F FUSE, 15A 300V SC15 Time Delay Control Panel LPF-FC Control Panel LPF-FC Parts Lid/Top AN8620560S, Sheet 1 Lid/Top AN8620560S, Sheet 2 Lid/Top AN8620560S, Sheet 3 Lid/Top AN8620560S, Sheet 4 LID/TOP AB86200700 Oil Vat Assembly AN86202800 Quik Disconnect Bracket Weldment Components AccessoriesDescription Accessory # Description Component #Components Electric Pressure Fryer Replacement Parts Wiring Diagram Diagram # Figure #LPF-F 208V/60HZ/1 or 3 Phase 240V/60HZ/1 or 3 Phase LPF 208V/240V, 3 Phase LPF 220V/380V1 or 3 Phase or 240V/415V 1 or 3 Phase LPF-FC 208V/3 Phase or 240V/3 Phase LPF-FC 208V/60HZ/1 Phase LPF-FC 240V/415V/3 Phase or 220V/380V/3 Phase LPF-F 220V/380V/3 Phase or 240V/415V/3 Phase Electric Pressure Fryer Electric Pressure Fryer Electric Pressure Fryer LI0804/1008