Bakers Pride Oven LPF-FC Care of the Shortening, LPF and LPF-F Operation, Start-Up LPF and LPF-F

Page 15

Electric Pressure Fryer

Operation

 

 

Care of the Shortening

Solid shortening should always be returned to the filter vat while in the liquid state. If this is not done, it will have to be heated to a liquid state. When using solid shortening, the fryer must be equipped with a pump heater. After filtering with solid shortening, the filter lines must be completely emptied of shortening. The pump heater will take care of any residual shortening in the pump, but cannot melt all of the shortening in the filter lines. The pump heater accessory may be purchased separately from BKI.

To extend the life of your shortening, for the best possible flavor in your products, and for economy and efficiency of operation, we urge you to follow these recommendations:

1.Use only high-quality frying shortening without additives, of low moisture content and with a high smoke point.

2.Press excess moisture from products before breading. The more moisture released in the shortening, the quicker it will break down.

3.Filter at least once a day or once every three loads during frequent cooking.

4.Clean any residue or crust formations from the sides and bottom of the pot each time you filter the shortening.

5.Add fresh shortening as needed to maintain the proper shortening level TO THE FILL MARK ON THE POT WALL.

6.DO NOT HOLD SHORTENING AT HIGH TEMPERATURE when the fryer is not in use. If you expect an elapsed time of one hour or more between cooking, close the lid and press the “0” button on the LPF-FC model. On Models LPF and LPF-F, set the thermostat to 150º F.

7.Shortening changes are determined by the quantity and type of food prepared. Excessive boiling and foaming are definite signs of shortening breakdown.

8.After you have finished frying for the day, filter the shortening and replace the filter pad. Also, thoroughly clean the pot of sediment and crumbs and empty the condensate pan.

LPF and LPF-F Operation

Start-Up (LPF and LPF-F)

1.Make sure the main drain valve is closed.

2.Fill pot with shortening to about one inch below the fill mark.

Risk of fire exists if the oil level drops below the minimum oil level. The level of oil within the pot must not fall below 5mm of the maximum oil level.

Use of oil/shortening older than the manufacturers recommendations for life of the oil is prone to surge boiling and flash fires. Follow the oil manufacturers guidelines for lifecycle of oil/shortening.

Overfilling the fryer pot with shortening could lead to serious injury. Ensure that the fryer pot is filled with shortening only to the fill mark when shortening is hot. Do not use any shortening other than what is specified in this manual and do not overfill the fryer pot.

The LPF/LPF-F fryer has a maximum temperature setting of 375º F (190º C). Do not use oil/shortening with a flashpoint less than 554º F (290º C)

13

Image 15
Contents Electric Pressure Fryer Warranty Information Table of Contents Safety Signs and Messages Safety PrecautionsSpecific Precautions Equipotential ground planeFull Disconnection Safe Work Practices Noncombustible Floors OnlyDo Not Overload The Basket With Food Never Loosen The Spin Handle Until Pressure Gauge Is At Zero Keep Safety Labels Clean and in Good Condition Safety Labels Installation Operation Controls and IndicatorsItem # Description Function Canceling The Stir OIL Function Pressing this button cancelsElectric Pressure Fryer Operation Care of the Shortening LPF and LPF-F OperationStart-Up LPF and LPF-F Cooking LPF and LPF-F KEY Display Mode DescriptionElectric Pressure Fryer Operation System Programming LPF-FC OperationStep Action Display Comments Product Programming Sequence Product ProgrammingProgram Product # ALF and BLF Automatic Step Action Display CommentsCooking LPF-FC Start-Up LPF-FCElectric Pressure Fryer Operation Recipes Cube Or Minute Steaks Whole Turkey 12 to 14 poundsWhole Duckling Pork ChopsMaintenance Assemblies Description Assembly #Item # QTY Description Drain Valve Replacement Thread Insert 10-24 Steel Drain/Motor/Piping Assembly VALVE,DRAIN SS BALL&PLT.CAR.STEM Control Panel LPF/LPF-F FUSE, 15A 300V SC15 Time Delay Control Panel LPF-FC Control Panel LPF-FC Parts Lid/Top AN8620560S, Sheet 1 Lid/Top AN8620560S, Sheet 2 Lid/Top AN8620560S, Sheet 3 Lid/Top AN8620560S, Sheet 4 LID/TOP AB86200700 Oil Vat Assembly AN86202800 Quik Disconnect Bracket Weldment Description Component # AccessoriesDescription Accessory # ComponentsComponents Electric Pressure Fryer Replacement Parts Figure # Wiring Diagram Diagram #LPF-F 208V/60HZ/1 or 3 Phase 240V/60HZ/1 or 3 Phase LPF 208V/240V, 3 Phase LPF 220V/380V1 or 3 Phase or 240V/415V 1 or 3 Phase LPF-FC 208V/3 Phase or 240V/3 Phase LPF-FC 208V/60HZ/1 Phase LPF-FC 240V/415V/3 Phase or 220V/380V/3 Phase LPF-F 220V/380V/3 Phase or 240V/415V/3 Phase Electric Pressure Fryer Electric Pressure Fryer Electric Pressure Fryer LI0804/1008