Sandwich/Fry Warmer | Maintenance |
4.Allow the equipment to cool to room temperature.
5.Remove and clean the Fry Warmer blower pan and pan insert.
6.Clean around the slotted holes at the air discharge on the blower box.
7.Clean the air intakes using a mild soap and water solution.
8.Sponge the inside and outside of the unit with a mild soap and water solution, being sure to clean all areas. Avoid getting water in the interior of the unit.
9.Wipe the parts and unit dry with a soft, clean cloth and replace the blower pan and pan insert.
Troubleshooting
Problem | Cause | Possible Solution |
|
|
|
Sandwich Warmer and/or | Power cords not | Make sure power cords are connected and circuit |
Fry Warmer will not turn on. | connected or circuit | breaker is on. If problem persists contact a |
| breaker supplying power | licensed electrician. |
| to the unit has tripped. |
|
|
|
|
Product is not holding it’s | Product temperature is | Make sure product is above 160 F when loaded. |
temperature | too low when loaded. |
|
| Or |
|
| Faulty component in | Contact an authorized BKI service agent for |
| heating circuit | corrective action. |
|
|
|
Fry Warmer |
|
|
|
|
|
Warmer chute is not | No power to unit. | Make sure that the circuit breaker at the power |
heating and perforated pan |
| supply is on and the Fry Warmer main power |
is not heating |
| switch is on. If problem persists, contact licensed |
|
| electrician. |
Warmer chute is heating | Fan has overheated and | Wipe the dust from the air intake louvers to allow |
and the perforated pan is | cut off | proper airflow and prevent fan overheating. Turn |
not heating |
| the power switch off. Wait 60 seconds. Turn the |
| Or | power switch back on. |
| Heating coil has failed | Contact an authorized BKI service agent for |
|
| corrective action. |
|
|
|
Noisy fan | Fan blade is dirty or fan | Contact an authorized BKI service agent for |
| bearings are failing | corrective action. |
Warmer chute is not | Ceramic heating | Contact an authorized BKI service agent for |
holding heat | element failure | corrective action. |
Sandwich Warmer |
|
|
Warmer is not heating | No power to unit | Make sure that the circuit breaker at the power |
|
| supply is on and the Sandwich Warmer main |
|
| power switch is on. If problem persists, contact |
|
| licensed electrician. |
| Or |
|
| Faulty component in top | Contact an authorized BKI service agent for |
| or bottom heating circuit. | corrective action. |
|
|
|
15