1 cfm = 0.47189 l/s
21 l/s = 3.6 m3/hr
Sizing (Example) for maximum airflow normally required.
HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per hour. To calculate, simply take the square footage of the house (including basement) and multi- ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.
Example: | SQFT of House | 1100 | |||
| Basement | 1100 | |||
| Total SQFT |
| 2200 | ||
| Height of ceiling |
|
| x | 8 |
| Cubic volume | 17600 | |||
|
| / | 60 | ||
| Maximum airflow required (CFM) |
|
| 293 | |
|
| x 0.35 | |||
|
|
|
| 103 |
* Always consult your local code for sizing requirements in your area.
Alternate Method
| Room classification | Number of rooms | CFM (L/s) |
| CFM Required |
|
|
|
|
|
|
| Master bedroom |
| x 20 cfm (10 l/s) | = | |
|
|
|
|
| |
| Basement | yes or no | if yes add 20 cfm / 10 l/s | = | |
|
|
| if no = 0 |
|
|
| Bedrooms |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Living room |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Others |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Kitchen |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Bathroom |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Laundry room |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
|
|
| Utility room |
| x 10 cfm | (5 l/s) | = |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
| ||
|
| Total Ventilation Requirements (add last column ) | = |