Amana HRV-150D, HRV-200D, HRV-300D manual Dmfc, Digital Multi-Function Control

Page 5

Introducing the NEW Heat Recovery Ventilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core. The HRV then distributes the preheated fresh filtered air throughout the home by direct ductwork installed specifically for the HRV or through the ductwork of a forced-air system.

FEATURES:

Compact Design

Electrostatic Filters (washable)

Balancing Dampers Included In Installation Kit

(not factory installed)

External Screw Type Dry Contacts For Push Button Timers, Dehumidistats, Crank Timer & Digital Control.

Easy Core Guide Channels For Removing Core

Better Packaging For More Protection In Shipping

OPTIONAL CONTROLS

• DMFC

– Digital Multi-Function Control

MD-4W – Mechanical Low Voltage Dehumidistat with On/Off Switch

MD-2W – Mechanical Low Voltage Dehumidistat

RT-15M – 15 Minute Push Button Timer

CT-30M – 30 Minute Crank Timer

• AQS

– Air Quality Sensor

External screw type dry contacts (provided)

HRV Series

HRV 150 & HRV 200

SPECIFICATIONS

CASE 22 gauge galvanized steel on the HRV-200 & 24 gauge galvanized steel on the HRV-150. Baked powder coated paint. Insulated with 1" (25 mm) high density polystyrene foam to prevent condensation and meet the requirements of the Underwriters Laboratories 94HF.

MOTORS Two (2) German-manufactured, factory-balanced ebm™ motors with backward curved blades. Motors come with permanently lubricated sealed bearings guarantee long life and maintenance-free operation. Seven (7) year limited limited warranty.*

CORE Aluminum heat recovery core configured for an efficient cross-flow ventilation. Core is 9" x 9" (229 x 229

mm)with a 15" (380 mm) depth HRV-150 or 12" x 12"

(305 x 305 mm) with a 15" (380 mm) depth HRV-200. Cores are manufactured to withstand extreme temperature variations.

FILTERS Two (2) Washable Electrostatic Panel Type Air Filters, HRV-150 is 8.5" (216mm) x 15" (380mm) x 0.125" (3mm), HRV-200 is 11.75" (298mm) x 15" (380mm) x 0.125" (3mm).

CONTROLS External three (3) position (Low/Stand By/Medium) rocker switch that will offer continuous ventilation. We offer a variety of external controls. (see optional controls)

DEFROST A preset 5 minute defrost sequence is activated at an outdoor air temperature of 23˚F (-5˚C) and lower.

During the defrost sequence, the supply blower shuts down

&the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy.

The unit then returns to normal operation for 25 minutes, and continues cycle.

SERVICEABILITY Core, filters, motors and drain pan can be easily serviced through latched access door. Core conveniently slides out with ease on an improved railing system. Electrical box, placed on the outside of the unit, can also be easily accessed.

* For details concerning warranties, please visit your local dealer.

The product is manufactured by Fantech, Inc. Fantech reserves the right to modify, at any time and without notice, any or all of this product's features, designs, components and specifications.

5

Image 5
Contents Ventilators Table of Contents Specifications FeaturesOptional Controls Air Quality SensorFan Performance Performance Data DimensionsAirflow TH port for recirculation defrost modelsDigital Multi-Function Control DmfcHRV-200 Fan PerformanceHRV-150 HRV-300D 91 % Power Volts 120 VAC Amperage Amps Total Phase Single Phase5TH port for recirculation defrost Type models only Operation Outside. The heat recovery ventiModes of Operation If the user wishes to stop the unit fromOptional Digital Control Operation ContdDmfc Operation Contd Optional Digital ControlLocation InstallationMounting Clothes dryer Range top Stovetop fan Central vacuum systemModel Installing Ducts Going to / from OutsideInstalling the Ducting To the Weatherhoods Supply AIR Ducting Installing Ducts to / from InsideDirect Connection From HRVDedicated Installation for Existing Home Installing Ducts to / from Inside ContdExhaust Air Ducting For new construction, the rigid ducts are run in the wallsDucting Fifth Port Units Installation ExamplesPartially Dedicated System Installation Examples ContdBe interlocked with the furnace blower Simplified InstallationOption Return/Return Method Option Supply/Return Method Air as so to increase the supply air’s temperature Pitot Tube Balancing ProcedureAIR Flow Balancing Place pitot tube a minimum of 18 from blower elbowsElectronic Balancing Motors HRV 150D & 200D only AIR Flow Balancing ContdAny repairs or maintenance MaintenanceTo Install the Clean Core and Filters Filters need to be checked regularlyTroubleshooting Electrical Connections Low Voltage Control Wiring ConnectionsElectrical Connections Contd Page Page Canada United States