Amana HRV-200D Maintenance, Any repairs or maintenance, Filters need to be checked regularly

Page 22

MAINTENANCE

CAUTION MAKE SURE UNIT IS UNPLUGGED BEFORE ATTEMPTING ANY MAINTENANCE WORK

The following components should also be inspected regularly and well maintained.

PRACTICAL

TIPS

To prevent electrical shock, check that the unit is unplugged before doing

any repairs or maintenance.

A yearly inspection is recommended to ensure the efficiency and trouble- free use of your system. Run through the system and verify the different operating modes.

The motor - The motors are factory balanced and lubri- cated for life. They require no maintenance.

The unit - The inside of the unit should be vacuumed

Filters need to be checked regularly

FILTERS

The filters (2) need to be checked and cleaned every three months or when they appear dirty. Wash in warm sudsy water (mild detergent) or use a soft brush vacuum. The filters should be replaced when they can no longer be cleaned properly.

HEAT RECOVERY CORE

The heat recovery core needs to be checked and cleaned every six months. The core can be cleaned using a mild soap and water. Rinse thoroughly. Handle with care. Hot water and a strong detergent will damage the heat recovery core. It is recommended to clean the core in the sum- mer or when the temperature is mild. Never clean the heat recovery core during winter.

yearly. Be careful not to damage any of the mechani- cal components and electri- cal connections.

The drain pan and drain line -

Units with drain lines should have their line and connec- tion checked regularly.

Outside hoods - The outside hoods need to be checked every season to make sure there are no leaves or insects blocking the airflow. Check regularly that there are no pollutants near the intake hood. Make sure they are clear of any snow accu- mulation during the winter months.

Clean Core and Filters Every 3-6 Months.

Unplugged before doing any repairs or mainte- nance

a)Open access door.

b)Carefully grip ends of core and pull evenly out ward. Core may be snug, but will slide out of the channel.

c)Once removed from the cabinet remove filters.

d)Wash core in warm soapy water (do not use dishwasher).

e)Install the clean filters.

f)Install clean core.

To Install the Clean Core and Filters.

a)First mount the bottom flange of the core guide into the bottom channel approximately 1/4” (6mm).

b)Mount the left or right side flange of the core guide approximately 1/4 “ (6mm) followed by the other side.

c)Mount the top flange of the core guide into the top channel approximately 1/4” (6mm).

d)With all four corners in place and the core straight and even, push hard in the center of the core until the core stops on the back of the cabinet.

NOTE: Some products may not be exactly as illustrated in Installation, Operation and Maintenance manual.

22

Image 22
Contents Ventilators Table of Contents Optional Controls FeaturesSpecifications Air Quality SensorAirflow DimensionsFan Performance Performance Data TH port for recirculation defrost modelsDmfc Digital Multi-Function ControlHRV-150 Fan PerformanceHRV-200 HRV-300D 5TH port for recirculation defrost Type models only Power Volts 120 VAC Amperage Amps Total Phase Single Phase91 % Modes of Operation Outside. The heat recovery ventiOperation If the user wishes to stop the unit fromOperation Contd Optional Digital ControlOperation Contd Optional Digital Control DmfcMounting InstallationLocation Clothes dryer Range top Stovetop fan Central vacuum systemInstalling the Ducting To the Weatherhoods Installing Ducts Going to / from OutsideModel Direct Connection Installing Ducts to / from InsideSupply AIR Ducting From HRVExhaust Air Ducting Installing Ducts to / from Inside ContdDedicated Installation for Existing Home For new construction, the rigid ducts are run in the wallsInstallation Examples Ducting Fifth Port UnitsInstallation Examples Contd Partially Dedicated SystemOption Return/Return Method Simplified InstallationBe interlocked with the furnace blower Option Supply/Return Method AIR Flow Balancing Pitot Tube Balancing ProcedureAir as so to increase the supply air’s temperature Place pitot tube a minimum of 18 from blower elbowsAIR Flow Balancing Contd Electronic Balancing Motors HRV 150D & 200D onlyTo Install the Clean Core and Filters MaintenanceAny repairs or maintenance Filters need to be checked regularlyTroubleshooting Low Voltage Control Wiring Connections Electrical ConnectionsElectrical Connections Contd Page Page United States Canada