Regulations on fuel-burning systems specify a maximum depression of 0.04 bar in such rooms.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi- mately 500-600 cm2 to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures.

When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation:

short and straight outlet hose

keep bends in outlet hose to a minimum

never install the hoses with an acute angle, they must

always follow a gentle curve only

— keep the hose as large as possible (120 mm Ø min.).

Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood.

8

Image 8
Contents 125 D Contents Extraction mode IntroductionRecirculation mode Summer/Winter Hood ConversionAppliances with 2 wires Electrical connection for the UKTechnical details Installation Safety warnings for kitchen unit installerPage Wall mounting Page Hood Operation Fixing the shelfSafety warnings for user Grease filter Maintenance and careOpening the grid Removing the filter Carbon filterCleaning Changing the light bulbSpecial accessories Something not working Allow the entry of fresh airService & Spare Parts 0990Page AEG Hausgeräte AG