Acme Kitchenettes PP-32 manual Clock Outputs, Start Time / Stop Time Definition

Page 45

PP-32

5.11 CLOCK OUTPUTS

The PP-32 has 4 clock outputs to control various devices, using the real- time clock. Refer to the installation setup section to activate the clock outputs (see sec. 5.14.3).

START TIME / STOP TIME DEFINITION

ON

OFF

START

STOP

TIME = 8:00

TIME = 9:30

OPERATION OF CLOCK OUTPUTS 1 AND 2 :

The first 2 clock outputs can use up to 8 programs and each program has up to 10 start and stop times. The user determines at what day each program starts being used (this day is directly related to the animal age). When a new program starts, the previous program is deactivated. Refer to section 5.13.3 to enable the proper number of clock programs for clock outputs 1 and 2.

An alarm is set off when a clock program that has not been properly set is activated (this applies to clock programs 2-8). This means that an alarm occurs when- ever a clock program that has all the same start and stop times (other than 12:00AM) is activated. In this case,

CLOCK OUTPUTS 1-2

PROGRAM 1

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 2

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 3

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 4

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 5

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 6

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 7

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

PROGRAM 8

ON / OFF 1 ON / OFF 2 ON / OFF 3 ON / OFF 4 ON / OFF 5 ON / OFF 6 ON / OFF 7 ON / OFF 8 ON / OFF 9 ON / OFF 10

the previous clock program keeps on running until the defective program is corrected.

OPERATION OF CLOCK OUTPUTS 3-4 :

Clock outputs 3-4 operate using 10 start and stop times.

CLOCK OUTPUTS 3-4

ON / OFF 1

ON / OFF 2

ON / OFF 3

ON / OFF 4

ON / OFF 5

ON / OFF 6

ON / OFF 7

ON / OFF 8

ON / OFF 9

ON / OFF 10

KOOLMASTER PP-32 REV.01 45

Image 45
Contents PP-32 Page Table of Contents Installation Alarm SettingsAuxiliary Outputs Animal AGE Clock Outputs HistoryPP-32 Do not Spray Water on the Controller PrecautionsFeatures Password Protection Front Panel Location of the ControlsShortcut Keys Destination Connection Mounting InstructionsNot ground the shielding AlarmDWR-F-1A Communication Hookup DIP Switch Table Setting the DIP SwitchesRoom Set Point this is the target temperature in the barn Current ConditionsStatic Pressure current static pressure in the barn Controller Programs Selecting a ProgramSelecting a Season PP-32 Adjusting the Room SET Point Minimum Ventilation Timer Adjusting Minimum Ventilations On-TimeMinimum Ventilation Adjusting Minimum Ventilations Cycle Time Inlet / Vent Door Settings Inlet Settings Potentiometer Feedback from InletsSetting DWR-F-1As ID numbers Adjusting the Air Inlet Compensation Vent Doors Operation Vent Door SettingsGroups of Static Pressure SET Points Influenced by Ventilation StagesInfluenced by the Outside Temperature Adjusting Vent Doors Open / Close / Off Times Adjusting Static Pressure Set PointsVent Doors Timer 2.4 2nd Group of Pressure Set Points at Stage Adjusting Stage Level for the Closing of Vent Doors2.5 2nd Group of Pressure Set Points at Outside T PP-32 Tunnel Curtain Tunnel Curtain Timer ModeTunnel Curtain Controlled by the Static Pressure Tunnel to Vent Doors Vent Doors to TunnelSelecting the First Tunnel Stage Adjusting Minimum Age for Tunnel VentilationAdjusting Curtains Operating Times Adjusting Curtains Timer Cycle Adjusting Static Pressure Hi and Lo Set PointsCurtains Timer Operation of FAN Stages FAN Stages SettingsFAN Stages Timer Adjusting Fan Stages Start/Stop TemperaturesAdjusting Fans Stages Timer PP-32 Operation of Heater Stages Heater SettingsAuxiliary Outputs in Heating Mode Auxiliary Outputs in Cooling ModeAuxiliary Outputs Adjusting Start/Stop Temperatures of Auxiliary Outputs Animal AGE Setting the Animal AgeStart Time / Stop Time Definition Clock OutputsOperation of Clock Outputs 1 Operation of Clock OutputsAdjusting Clock Output Start and Stop Times Adjusting Starting Day of Clock Programs Resetting Histories Average Temperature HistoryHistory Individual Temperature Sensors History Outside Temperature Sensor HistoryRelative Humidity History Heater Run Time History Water Consumption HistoryPP-32 Alarm Log Alarm SettingsRegular Temperature Alarm Detection Setting Alarm LimitsOustide Temperature Influence on Alarms Adjusting Hi/ Lo Temperature Alarms Alarm Detection with Outside T InfluenceAdjusting the Outside Temperature Influence Adjusting Critical TemperatureLO Static Pressure Alarm Adjusting Static Pressure AlarmsSet the Lo Alarm Limit to Off to deactivate this feature HI Static Pressure AlarmAdjusting High/Low Delays Adjusting the Open-Time for the Hi Static Pressure Alarm Resetting the Alam LogStep-by-Step Installation Guide InstallationPP-32 Entering the Installers Password Password SettingsModifying the Installers Password Installation Setup Use Static Pressure ? Auxiliary Output ModeStatic Pressure Set 10.# of InletsInstaller Password Use Outside Temperature Sensor ?16.# of Clock Outputs 17.# of Clock Programs for Clock Outputs 1Assigning Sensors to the Room T and Fan Stages Sensor AssignmentAssigning Sensors to Air Inlets Assigning Sensors to Heater StagesAssigning Sensors to Auxiliary Outputs √√√ Relay Assignment Setting Time and DateAn empty template is available at the end of this manual Relay Assignment ExampleTimer Relays on FAN Stages To .7.2 to set the timers on and OFF time settingsAssigning Fan Stages Relays Assigning Heater Stages Relays Assigning Relays to Vent DoorsAssigning Vent Doors Open / Close Relays Assigning Curtains Open / Close Relays Assigning Relays to the Tunnel CurtainAssigning Relays to Auxiliary Outputs Assigning Relays to Clock OutputsAssigning Relays for the Lo Static Pressure Alarm Calibrating the Water Counter Advanced Settings Temperature CurveSetting the Temperature Curve PP-32 Minimum Ventilation Curve Setting the Minimum Ventilation CurvePP-32 Humidity Control Adjusting Relative Humidity Set PointRH Compensation on Minimum Ventilation Humidity Compensation on MIN. VentilationAdjusting Mist or Kool-Cel Shutoff Adjusting Heater Timer CycleHumidity Compensation on Heaters PP-32 Calibrating Sensors Calibrating Room and Outside T SensorsCalibrating the Relative Humidity Sensor Select 8.Vents/Static P from Calibrating the Static Pressure LevelTest Mode Technical Specifications Factory Settings Using the Configuration Module Start Configuration Press +/- to startContact Information Sensor Assignement Sensor Assignment Template see secInstallation Setup Template see sec Installation SetupRelay Assignment Template see sec ProcedureOUTPUT/ Relay # Index Installer password Keys see also buttons Setup

PP-32 specifications

The Acme Kitchenettes PP-32 is a versatile and compact solution for modern living spaces, ideal for those seeking functionality without sacrificing style. This kitchenette is perfect for apartments, studios, and locations with limited space, offering a blend of convenience and elegance.

One of the standout features of the PP-32 is its efficient layout. The kitchenette is designed with a compact footprint that maximizes usability while fitting easily into small areas. It includes essential components such as a sink, cooking surface, and storage, all seamlessly integrated to provide a fully functional cooking experience. The PP-32 comes equipped with a two-burner electric cooktop, allowing you to prepare meals with ease. This cooking surface is engineered for quick heating and energy efficiency, making it perfect for busy lifestyles.

The stainless steel sink is another significant aspect of the PP-32, designed to resist tarnishing and scratches while maintaining a sleek appearance. Its integrated faucet ensures that you have the water access needed for cooking or cleaning up. Additionally, the cabinetry includes ample storage space, featuring cabinets and drawers designed to hold cooking essentials, utensils, and pantry items. This storage solution is both functional and aesthetically pleasing, with a modern finish that complements any décor.

In terms of technology, the PP-32 incorporates advanced features that enhance its usability. The kitchenette is equipped with energy-efficient lighting that brightens the workspace while keeping energy consumption low. Additionally, the inclusion of easy-to-clean surfaces ensures that maintenance is simple, allowing for a tidy living environment.

The Acme Kitchenettes PP-32 also boasts a straightforward setup process, making it easy to install even in tight areas. With its thoughtful design and modern features, this kitchenette represents an ideal solution for those who value both efficiency and style in their living spaces.

In conclusion, the Acme Kitchenettes PP-32 provides a seamless blend of functionality, technology, and contemporary design. It caters to the needs of urban dwellers and those in smaller living setups, ensuring that cooking and meal preparation becomes an enjoyable experience. Whether for personal use or in rental properties, the PP-32 stands out as a reliable and attractive kitchenette option.