16 | Medalist 1080sl SCSI Installation Guide, August 1995 |
Basic troubleshooting
Warning. Always turn off the system before changing jumpers or unplugging cables and cards.
If your drive does not respond or function properly when you turn the power on following the hardware installation, perform these basic checks:
∙Check all cards. Make sure all cards are seated securely in their slots on the motherboard.
∙Check all cables. Make sure all cables are securely con- nected. A damaged ribbon cable or connector strain relief can cause the SCSI bus to fail.
Verify that the pins 1 of each device on the cable are aligned. Use the
Caution. Improperly aligning or
∙Check the SCSI ID. Make sure the drive’s SCSI ID does not conflict with that of another device.
∙Check the terminator configuration. If the drive is at the end of the bus and external termination is not used, the drive’s terminator must be enabled. Disable or remove termination on all devices between the drive and the device at the other end of the bus.
If the drive is not the last device on the bus or if external termination is used, be sure to remove the jumper that enables the drive’s termination.