Pitco Frialator L20-299 operation manual Daily Cleaning, Thermostat Calibration Check

Page 13

CLEANING AND MAINTENANCE

MAINTENANCE AND ADJUSTMENTS

Daily Cleaning

Your appliance should be cleaned every day to maintain peak performance, proper sanitation and appearance. Perform the following procedures daily.

a.Wipe up any shortening/oil that spills onto the exterior of the appliance. This should be done with a clean soft cloth while the shortening/oil is still warm.

b.Use warm water with a mild detergent to clean surfaces. Be careful not to get water into the shortening/oil and be sure to completely remove any detergent from the fry tank. Use a non- abrasive scouring powder or pad to clean stains if necessary.

NOTICE

Maintenance and repairs should be performed by qualified personnel. If you are unsure, contact the factory, factory representative to locate the nearest qualified Service Company.

Thermostat Calibration Check

NOTICE

Thermostat calibration requires that the temperature of the appliance be raised above

boiling. If you have water in the tank you will need to drain it, dry it and fill it with

shortening/oil. Follow the filling instructions in this manual.

To check the calibration of your appliance, refer to the following procedure.

a.Remove the tube rack from the tank.

b.Place the tip of a digital thermometer probe in the shortening/oil approximately one inch above the temperature sensor.

c.Light the pilot as described in this manual, set the thermostat to 325°F (163 °C) and allow the shortening/oil to come up to temperature. Watch the thermometer closely as the temperature rises.

d.If the shortening/oil temperature reaches 350°F (167 °C) and the burners do not turn off, turn the thermostat down. Keep lowering the thermostat setting until the burners go out.

CAUTION

If the burners do not shut off at the LOWEST thermostat setting, the thermostat may be

defective. Contact your local service company.

e.Let the appliance cycle 4 to 6 times before checking the temperature. Compare the thermometer temperature against the thermostat setting. If the values are more than 5°F (3 °C) apart, calibrate the thermostat using procedure in this manual.

10

Image 13
Contents English For Your Safety Troubleshooting Leg/Caster Installation and Leveling Assembly and LevelingChecking Your New Appliance Installation Heat Deflector InstallationInstallation Clearances Gas ConnectionVentilation and Fire Safety Systems Fuel Supply Line Leak and Pressure TestingQuick Disconnect Gas Connection Types of Fire Extinguishers and Detection EquipmentBurner Ignition Systems Initial AdjustmentsLighting Instructions Pilot Flame AdjustmentMain Burner System Adjustment Initial Cleaning Filling the tank with liquid shortening/oil Filling the TankFilling the tank with solid shortening/oil Operating InstructionsAppliance Start-Up Power FailureAppliance Shutdown Thermostat Calibration Check Daily CleaningBoil Out Procedure Weekly Cleaning General CleaningThermostat Calibration Ventilation Hood Maintenance Basic Troubleshooting Flow Chart TroubleshootingWiring Diagram This page Left Intentionally Blank This page Left Intentionally Blank Covering Model 65 Series Fryer