Pitco Frialator L20-299 operation manual Lighting Instructions, Pilot Flame Adjustment

Page 8

INSTALLATION/OPERATION

WARNING

During operation there is an open flame inside this appliance. The unit may get hot enough to set near by materials on fire. Keep the area around the appliance free from combustibles.

Lighting Instructions

For manual pilots, refer to the following instructions.

WARNING

If pilot extinguishes, wait 5 minutes before attempting to relight the pilot to allow any built

up gas to dissipate.

a. Open gas supply valves to the appliance.

b. Turn the thermostat control knob counterclockwise to the OFF position.

c.Turn the gas valve knob counterclockwise to the PILOT position. Push knob in and hold a flame to the pilot until the pilot ignites; this may take a little while the first time you light the pilot because of the air in the lines. Once lit, hold the knob in for approximately one minute and then release.

d.If the pilot goes out, wait 5 minutes and repeat step C. If after three tries the pilot will not remain lit, refer to the operator troubleshooting section of this manual.

e.Once a pilot flame has been established, turn the gas valve knob counterclockwise to the ON position.

f.Set the thermostat control knob to the desired temperature setting, The main burners will ignite and be controlled by the thermostat.

Pilot Flame Adjustment

For manual pilots, refer to the following instructions. Perform this procedure once the pilot is lit and ensure that the thermostat is turned to the OFF position.

NOTE: This procedure requires a DC millivolt meter set to a scale of 0-1000 mV.

Using test leads with sharp probes will help in taking the required readings.

a. Locate the thermopile wires coming from the pilot to the gas valve.

b. Using the positive (+) test probe, connect the probe to the top PP terminal with the red wire.

c.Connect the negative (-) test probe to the bottom PP terminal with the white wire.

d. The output level should be 550mv ± 50mV. If this level is not correct, remove the cap screw and adjust the screw in and out to achieve the proper millivolt level. Replace cap screw.

Note: Allow 3 to 5 minutes between flame adjustments to allow the reading to stabilize.

5

Image 8
Contents English For Your Safety Troubleshooting Checking Your New Appliance Assembly and LevelingLeg/Caster Installation and Leveling Heat Deflector Installation InstallationInstallation Clearances Gas ConnectionFuel Supply Line Leak and Pressure Testing Ventilation and Fire Safety SystemsQuick Disconnect Gas Connection Types of Fire Extinguishers and Detection EquipmentInitial Adjustments Burner Ignition SystemsPilot Flame Adjustment Lighting InstructionsMain Burner System Adjustment Initial Cleaning Filling the Tank Filling the tank with liquid shortening/oilFilling the tank with solid shortening/oil Operating InstructionsAppliance Shutdown Power FailureAppliance Start-Up Daily Cleaning Thermostat Calibration CheckThermostat Calibration Weekly Cleaning General CleaningBoil Out Procedure Ventilation Hood Maintenance Troubleshooting Basic Troubleshooting Flow ChartWiring Diagram This page Left Intentionally Blank This page Left Intentionally Blank Covering Model 65 Series Fryer